







Descriptions
GEYA G2R Din Rail 2P 4P ATS Dual Power Automatic Transfer Switch Electrical Selector Switches Uninterrupted Power 25A 40 63A 110V/220V BEST ATS QUALITY IN Buydo---SILVER CONTACT POINT & RED COPPER PARTS & STABLE RELAY CONTROL City Power ⇆ Generator G2R ATS Usage Precautions: 1 220V ATS should not be used with a voltage less than 185V, in any other case the coil may perhaps burn out 2 110V ATS should not be used with a voltage less than 90V, otherwise the coil might burn out three The switch cannot be manually switched when in computerized mode, in any other case the coil may well burn out 3 4P ATS make certain correct connection of phase sequence,otherwise the contacts may possibly burn out General GEYA G2R-63 automated move swap is a PC category rare change-over switch, with two-station design (commonly used for A and standby for B), compatible for AC programs with AC 50-60hz and rated recent 6A-63A The leading operate of the automatic move switch is when the foremost strength (common strength delivery A) fails, the ATS will robotically switch to the backup power (Backup power delivery B) to proceed working (switching velocity <50 milliseconds), which can efficiently solve the troubles caused by strength outages When both A and B have electricity, precedence is using A Power NOTE: 1 Manual/automatic operation can ensure the opening and shutting functionality of electric operation, but in handbook operation , there's no guarantee due to the different _opening/closing speeds of the operators In guide operation, there may be possible for immoderate silver alloy loss Therefore, the selector swap should only be pulled to the guide function in spite of everything power has been bring to an end for inspection and maintenance of the working method and speak to information 2, Normally, pull the selector swap to the electrical function When guide operation is required, pull the selector switch to the manual role After manual operation is complete, pull the selector swap from the manual role to the automatic function The control circuit TSE is instantly energized After the exchange over is completed, the interior swap will damage the coil in the control circuit, and the coil can work usually at 85%-110% of the rated working voltage Too low enter voltage can cause the coil to overheat and burn out Attention!When handbook operation the mode alternative change must be in "manual" role Company Information





Révision
0 people rated this product
GEYA G2R Din Rail 2P 4P ATS Dual Power Automatic Transfer Switch Electrical Selector Switches Uninterrupted Power 63A 110V 220V




Livraison et retours gratuits
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection
