1way
Product introduction:
1, 5V 240V stable state relay 2A, output resistive variety insurance coverage
Wire 240V 2A
2, size: 25*34*25 (length * width * height) internet weight: 13g
3, the input strength supply: 5V DC (160MA)
4, the input control sign voltage:
(the state of the 0-1 low point relay ON)
(the state of the two excessive level relay OFF)
5, the blue KF301 terminal is attached to the road of control more handy
Module interface:
Input part:
DC+: connect the power delivery superb (press the relay voltage energy supply)
DC-: the cathode of a power supply
CH: relay module sign set off finish (low level set off effective)
High level and low point of meaning:
High level set off refers to the signal trigger end (IN) and the detrimental electrode of the ability between
A positive voltage, veritably with the fantastic pole of a power delivery and a trigger terminal connection
A trigger mode, when the trigger finish has a favorable voltage or to set off voltage, the relay is attracted
Low level trigger refers to the sign triggering voltage between the top and the negative electrode of the ability supply
OV, or set off terminal voltage lower voltage than the superb power supply,
Low to voltage can be triggered, make the relay, usually will power
The adverse electrode and the triggering finish of a trigger connected, so that the relay is attracted
Electrical parameters:
Voltage edition 5V
Quiescent latest 0mA
The working recent of 12
Trigger voltage 0-1
Trigger recent 2mA
Use merchandise that:
Power delivery of 1 modules: power delivery must be DC electric
Pressure to conform with the voltage relay
The 2 wiring method:
When the signal triggering finish of low level trigger, the relay will connect, kit electrical paintings
2way
Products:
1, 5V solid state relays 240V 2A, output with resistive fuse 240V 2A
2 Size: fifty five * 33 * 25 (L * W * H) Weight: 21
3, the enter strength supply: 5V DC (160MA)
4, the enter control sign voltage:
(0-2 low state relays ON)
(3 state high relay OFF)
5, blue KF301 terminals to the management line is extra convenient
Module Interface:
Input section:
DC +: advantageous energy delivery (according to the relay voltage supply)
DC-: adverse one
CH1: 1 relay module sign triggering finish (low to trigger active)
CH2: 2 relay module sign triggering finish (low to trigger active)
High and occasional meanings:
High trigger finger is a sign to the set off terminal (IN) between the adverse strength supply and has a forward voltage, veritably with a trigger and set off the superb terminal linked to the flexibility supply, when the trigger finish has brought about wonderful voltage or reach When the voltage, the relay is energized
Low voltage set off refers to OV, or trigger voltage lower than the voltage delivery terminal fantastic signal to trigger the tip of the unfavourable energy between low adequate to trigger the voltage, so that relay, veritably the A unfavorable set off and the trigger end of the flexibility connection, the relay is energized
Electrical parameters:
Voltage edition quiescent latest operating recent set off voltage set off current
1 channel 5V 0mA 12 0-2 2mA
2-way 5V 0mA 22 0-2 2mA
Product description:
1 The module energy supply: Power ought to be DC voltage to match the voltage relay
4way
Products:
1, 5V stable state relays 240V 2A, output with resistive fuse 240V 2A
2 Size: 106 * 56 * 25 (L * W * H) Weight: 70g
3, the enter energy supply: 5V DC (160MA)
4, the input management sign voltage:
(0-2 low state relays ON)
(3 state high relay OFF)
5, 2 pin and blue KF301 terminals to the control line is extra convenient
Module Interface:
Input section:
DC +: effective power supply (according to the relay voltage supply)
DC-: adverse one
CH1: 1 relay module signal triggering end (high point trigger active)
CH2: 2 relay module signal triggering finish (high level set off active)
CH3: 3 relay module signal triggering end (high point set off active)
CH4: 4-channel relay module sign triggering finish (high level set off active)
CH5: five relay module sign triggering finish (high point trigger active)
CH6: 6 relay module signal triggering finish (high point trigger active)
CH7: 7 relay module sign triggering end (high point trigger active)
CH8: eight channel relay module sign triggering finish (high level trigger active)
High and occasional meanings:
High trigger finger is a signal to the set off terminal (IN) between the negative power supply and has a ahead voltage, assuredly with a set off and trigger the high-quality terminal linked to the ability supply, when the set off end has triggered fantastic voltage or reach When the voltage, the relay is energized
Low voltage set off refers to OV, or set off voltage lower than the voltage delivery terminal high quality sign to trigger the end of the destructive energy between low satisfactory to set off the voltage, so that relay, usually the A damaging set off and the set off finish of the power connection, the relay is energized
Electrical parameters:
Voltage version quiescent latest operating recent trigger voltage trigger current
1 channel 5V 0mA thirteen 2 2mA
2-way 5V 0mA 26 2 2mA
3-way 5V 0mA 37mA 2 2mA
four 5V 0mA 48mA 2 2mA
5-way 5V 0mA 59mA 2 2mA
6-way 5V 0mA 70mA 2 2mA
7 Road 5V 0mA 81mA 2 2mA
8 5V 0mA 90mA 2 2mA
Product description:
Power delivery modules: Power needs to be DC voltage to check the voltage relay