General
SOPR-3DE series electronic overload and phase lost relays are designed toprevent the mess ups originated from motor heat
Setting
D-Time: Set two to three seconds longer than the motor starting time
O-Time: Over-current run time lower than the motor&;s endurance time with over-current
LOAD: Set over 110% of the motor started recent or beneath 120% of its operating recent
Relay Condition
When Powered: 95(COM) and 96(NC)is open circuit,95(COM)and 98(NO) is short circuit
When Tripped: 95(COM) and 96(NC) is brief circuit, 95(COM)and 98(NO) is open circuit
Configuration Menu
Trip Cause Indication
Maintenance
Periodic checking out of TEST button is usually recommended to guarantee the full protectionand continually as preventive maintenance
Switch off the gadget and release from connections the trunk of device with a swab
Don&;t use any conductor or chemical may damagethe gadget yes machine works after cleaning
Specifications
Current Range : Type05) 1-6A
Type30) 5-30A
Type60) 5-60A
Type120) 10-120a
Operating Voltage(Un): Tpye24) 24VAC/DC
Tpye220) 90-260VAC
Operating Frequency: 50/60Hz
Operating Power: <2W
Operating Temperature: -20℃·····+55℃
Waiting(t): D-Time 1-30s
O-Time 1-10s
Asymmetry Set: %±1
Contact: 5A 250VAC Resistive Load
Connection Diagrams: 35mm Din Rail(D) or Pane(P)
Dimensions
Connection Diagram