







विवरण
Features ■ Compact Design ■ Overload / Phase Loss / Locked Rotor Protection ■ Independently Adjustable Starting Trip Delay & Operating Time ■ Wide Current Range:0~600A ■ Wide Operating Voltage Range ■ PWR & Trip Indication LED ■ Manual / Electric Reset ■ Ambient Insensitive ■ Low Energy Consumption ■(No Volt Release/Fail-safe Operation)→N Type ※Single-phase, three-phase out there (No Volt Release/Fail-safe Operation)→N Used for - Low Voltage Induced Electromotor (600V Level) Protective Relay - Break-Down Watch Current Relay - Alternative Replacement for the Existing Relay Protetcion Protective Item Operating (Trip) Time Over-Current = O-TIME Phase Loss = O-TIME Locked Rotor = D-TIME+O-TIME LED Ammeter Function: After the motor runs smoothly, flip the overcurrent atmosphere knob slowly counter clockwise to the pink indicator light, which is 100 percent of the actual operating recent And then flip the knob clockwise to just turn off the red light at this level for the particular working latest cost of about 103% Run / Operation Indicator: Relay Trip: Red LED Power / ordinary working status: Green LED Manual / Electric Reset With test button ehld down,the pink LED is on and the product will day out after O-TIME The relay may be de-energized when RESET button is driven or the control power is disconnected Set After the set up is whole the settings as follows Set knob: D-TIME(Delay Time) Set two to three seconds longer than the motor starting time Set knob: O-TIME(Over-current run time) Set lower than the motor&;s persistence time with over-current Set knob: Load(Rated Current) Set over 110% of the motor&;s rated latest of beneath 120% of its working latest TEST Instruction With check button held down,the orange LED is on and the product will day out after O-TIME The relay will be de-energized when RESET button is driven or the management energy is disconnected LED Indication Item PWR(Green)LED Trip(Red)LED Power ○ × Normal Running ○ × Trip × ○ Specifications Current Range : Type05) zero Type30) 3-35A Type60) 5-70A Type600) Use an exterior CT(secondary 5A)over 60A with 05 type Operating Voltage(Un): 12VAC/DC, 24VAC/DC, 110VAC, 90~260VAC, 180~460VAC Operating Frequency: 50/60Hz Operating Power: <2W Operating Temperature: -20℃·····+55℃ Waiting(t): D-Time 0, O-Time 0 Asymmetry Set: %±10 Contact: 5A 250VAC Resistive Load Mounting: 35mm Din Rail(D) or Pane(P) Dimensions Construction Connection Diagram





समीक्षा
0 people rated this product
Samwha-Dsp SOPR-SS1 Electronic Overload Motor Protector Thermal Relay





मुफ़्त शिपिंग और वापसी
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection
