Functional ZigBee Smart Human Presence Sensor
Featured as human presence,human static,human micro movement and human movement movement detection to discover the presence or absence of folk in the area,even to discover the static state equivalent to physique of employees sleeping accurately with mmWave Radar Detection featured.
Works with Zigbee 3 Hub
ZigBee Hub as Control Center,Tuya ZigBee gateway is required for this ZigBee human presence sensor,performing because the center bridge for all Tuya ZigBee smart devices with extremely safe signal and a extremely good necessity for whole-house intelligence.(note:Tuya ZigBee hub is highly commended for its wider compatibility than different hubs)
Advanced New Design with Multiple Settings
8 kinds of Common Parameter Settings for sensors assist setting, and five sorts of Control Parameter Settings help setting.
Supports two set up methods.
You can install it on the ceiling or wall utilizing double-sided adhesive or growth screws. The machine helps connecting to 85-265V AC power.
More accurate radar measurement.
5 and 24G versions optional, and in keeping with different accuracy requirements, you possibly can choose the version that's extra appropriate for you.
Perceived Light Intensity for SmartScene Linkage
(1) visual display unit in Tuya Smart APP permits its smart operate as clever scene linkage with other clever instruments ,especially your place lights to ON/OFF robotically because the brightness changes;Besides,you can intelligently linkage the sensor to different clever home instruments for domestic automation.
(2) this device, the Illumin threshold (0-420 Lux) could be set the device is in local
(automatic) mode operation, it may be
robotically managed in conjunction with the illumin threshold. When the actual luminance charge is less than the set illumin threshold, the native mode of the relay(breaker mode) is completed normally. When the actual luminance value exceeds the set illumin threshold, the relay stays closed despite whether or not somebody is present.
Relay function(Breaker)
If you like someone to robotically turn on the light, you would possibly attempt instantly connecting the lamp to the sensor, that might save an clever switch. If you simply prefer to use it as a sensor, you'll ignore it relay modes would be set within the APP.
Standard (cloud linkage): It would be remotely
controlled to reveal on/off the relay throughout the APP.
Local (automatic): If somebody is present, the relay
will mechanically turn on, in any other case it will flip off.
no longer support: Disable relay.
Ceiling required Hole Size:60-65mm
Specifications
Network: ZigBee 3
input: 110-265VAC.
Working temperature: -10℃~+50℃
Sensitivity: 1-9(default 7)
5 Beam Angle:120X120
24G Beam Angle:110X110°
five Sensing distance: 0-11m(default 6m)
24G Sensing distance: 2(default 7m)
5 Sensing radius: 2(Presence),4~5(motion).
24G Sensing radius: 2-3m(Presence),4~4(motion).
Illuminance Sensor: 0~500 Lux(The approximate brightness of the environment wherein the sensor is located).
Departure Delay: 0~25 min;It is suggested to set it to no lower than 15S. Otherwise, detection could also be missed.
Transmitting Power: 3~5 dBm(5), 10dBm(24G).
Working Humidity: 5~90% RH(No Condensation).
Protection Level: IP20.
Relay Load: Resistive load≤3000W LED≤300W.
Restricted Usage Scenarios
5: In elevators, metal sealed toilets, and same all metalsealed spaces; Scenarios where the plane subject of metal decorative supplies exterior the non ceiling area exceeds 20%.
24G: The restrictions should not significant to put in the zigbee presence sensor?
1. Select a suitable set up location in response to the scope of the detection area to be sure that the detection area can be effectively covered;
2. The edge diameter of the equipment is 75mm, and the embedded part is 60 * 58mm (cylindrical). Circular holes with a diameter of 60-65mm could be opened at the ceiling, and the minimal reserved space at the peak is rarely less than 75mm;
3. Clip the flexibility and signal wires onto the package (gently clip the wires, in any other case the wires may well even be easily cut) and introduce them into the ceiling opening;
4. Insert the mechanical device into the ceiling gap to finish the establish