40A 20A Solar Charge Regulator Fit for Street Light System with 12V 24V Auto LCD Display Controller with Load Dual Timer Control
Note:
It is nice well suited MPPT + PWM Solar Controllers ,not one hundred pc Ture MPPT
Please contact us for checking extra details if obligatory
Thank you
Product Introduction
40A T40 Solar Charge Controller Dual timer
This is a three-time controller into the night operating time,an interval of remainder of pause time,Dawn working time(morning light function), the person can in line with their needs,set a distinct time
A:time(evening working) B:time(pause working) C:time(dawn working)
This is a compatible MPPT price controller PWM intelligent / effective / energy saving, he not only has efficient MPPT controller charging function to routinely song the maximum power point, 10% -30% larger than the ordinary controller charging efficiency, additionally has standby calories saving, greater than 30% energy than normal controller, the standby energy consumption of only 10mA-15mA
LCD display screen show
Battery opposite discharge protection
Easy operation interface
Battery opposite polarity protection
MPPT+ PWM charging mode
Battery under voltage protection
Parameter consumer can reset Overload
Short-circuit defense
A key to restore the manufacturing unit settings
USB 5V charging ( 500mA(White) 1500mA(Sliver) for cellular phone
A key to open and shut the burden
Automatic temperature repayment operate
Package listing
1 1x solar controller
2 1x consumer handbook
3 1x temp sensor
Product Pictures
Parameters / Model
T10
T20
T30
T40
Maximum energy latest
12A
20A
30A
40A
Installation Lin(mm2)
4mm2
8mm2
10mm2
12mm2
Installation Line(AWG)
10(AWG)
8(AWG)
7(AWG)
6(AWG)
Weight
280g
300g
475g
480g
Dimensions
143×89×46(mm)
187*97*61(mm)
System load loss
≤13mA
Loop Buck
≤100mV
Battery waft voltage
13(12V system)/27(24V system)
Battery (under voltage) defense
10(12V system)/21(24V system)
Battery (under voltage) restoration voltage
12(12V system)/25(24V system)
Charge mode
MPPT+PWM MODE
Operating Temperature
-10°C~60°C
Storage Temperature
-30°C~70°C
Humidity requirements
≤90%, No condensation
Temperature reimbursement
-4mV/Cell/°C
Temperature Probe (built components)
NTC 100K thermistats
Maximum open circuit voltage of the photo voltaic panel
18V-24V(12V system)36V-48V(24V system)
Solar panels most open circuit voltage (V)
≤48V
(Cases) 12V method traditional configuration
T20 20A Solar Charge Controller Dual timer
This is a three-time controller into the evening operating time,an period of remainder of pause time,Dawn operating time(morning mild function), the consumer can in step with their needs,set a different time
Dual Timer operate