Single-phase 220V tender start module use range:
220V (50Hz, 60Hz)
230V (50Hz, 60Hz)
240V (50Hz, 60Hz)
The above three voltages are universal for this product
This product is often used for motors with the following voltages:
Petroleum, chemical, fire, construction, metallurgy, constructing materials, mining, environmental defense and other fields
Fans, pumps, belt conveyors, ball mills, vehicle washing machines, conveyors and compressors
It is an ideal alternative for traditional star/delta conversion, auto-coupling buck, magnetic control buck, inverter and other step-down beginning instruments
Applicable locations
1; petroleum, chemical, fire, construction, metallurgy, building materials,
mining, environmental protection and other fields
Can be widely utilized in fans, pumps, belt conveyors, ball mills, conveyors
and compressors and other a lot
2: It is an ideal alternative for traditional star/delta conversion
An ideal replacement for auto-coupled buck,magnetron buck,
inverter and other step-down starters is secure and reliable
220V single-phase motor comfortable beginning module (motor conversion method)
model:
SSR-20WA-R1 (1kw)
SSR-40WA-R1 (1)
SSR-60WA-R1 (2kw)
SSR-100WA-R1 (4kw)
SSR-150WA-R1 (6kw)
SSR-200WA-R1 (8kw)
According to the actual operating latest 5 times: energy ÷ voltage × 5
in case:
Your motor is 8000w power ÷ 220v voltage × 5 = (181 should choose 200WA) should desire the parameter closest to that model
our comfortable birth is universal for the motor, despite whether the motor has a capacitor or no longer
If your motor is operating for an extended time, the motor above 2000W needs to be geared up with a heat sink
Single phase motor compared to starter module
Voltage compatibility:
(220V + 0V = single-phase 220V, AC)
(230V + 0V = single-phase 230V, AC)
(240V + 0V = single-phase 240V, AC)
(220V + 220V = two-phase 380V--400V, AC)
Frequency: 50Hz, 60Hz
Soft delivery time is adjustable between 0-30 seconds (soft start time refers to the entire process 0-220V, 0-380V)
Slowly modify the starting voltage from 0-50? Reaching the rated voltage (220-380V)
There are two methods to use it:
1 After closing the switch, the most important energy may be energized and begin smooth beginning
2 Use the swap to control, close the smooth begin to start, open to stop
The gentle birth module has 2 programs:
1 has delicate delivery and no comfortable give up
2 has gentle beginning and smooth give up applications (start as many V stops as V stop)
note:
1 not practice voltage to the change
note:
1 Do not use a multimeter on the load side to guage the quality of the product!
2 Subject to area check
Working surroundings temperature differ -25°C~60°C