80A 60A Solar Charge Controller LCD Display USB 5V 12V 24V Auto Controllers Light Timer Control Solar Cell Panel Charger
This is a three-time controller into the evening(evening)working time, an period of relaxation or pause time, Dawn operating time(morning mild function), the person can in keeping with their needs, set a different time
A:time(evening working)B:time(Pause working)C:time(dawn working)
This is a well matched MPPT price controller PWM intelligent/efficient/energy saving, he not just has effective MPPT controller charging function to automatically song the utmost strength point,10%-30% higher than the standard controller charging efficiency, additionally has standby calories saving, greater than 30% energy than regular controller, the standby strength consumption of solely 10mA-15mA
Note: It is superb well matched MPPT + PWM Controllers, now not 100% MPPT
Parameter table:
L-60
L-80
Maximum Power Current
60A
80A
Installation Lin(mm2)
16mm2
20mm2
Installaton Line(AWG)
4(AWG)
2(AWG)
Weight
800g
900g
Peak power of photo voltaic cell panel (Max Wp)
800W
1000W
Battery skill configuration
600AH
800AH
Dimensions
188*128*61(mm)
Battery glide voltage
13(12V system)/27(24V system)
Battery (under voltage) defense
10(12V system)/21(24V system)
Battery(under voltage)recovery voltage
12(12V system)/25(24V system)
System load loss:<=13mA
Loop Buck;<=100mV
Operation Temperature :-10degC~60degC
Storage Temperature :-30degC~-70degC
Operation Temperature :<=90%,No condensation
Temperature repayment :-4mV/Cell/degC
Maximum open circuit voltage of the photo voltaic panel
18V~24V(12V system) 36V~48V(24V system)
Solar Panel most open circuit voltage
<=48V
LCD Operating Interface Description :
Installation:
1 Qi set up tools and materials,and cable matching appropriate cable
2 that the present desity<4A/mm2 That may also help cut the line stress drop the set up site meets the applicable safety requirements,avoid damp,dusty,flammable,explosive and corrosive gases
three the controller fixed to the vertical plane,see Section V mounting aperture and gap spacing order to guarantee a good controller cooling conditions,the controller at the bottom of every reserved 10cm space
4 shown at the right wiring sequense:load,battery,solar Battery plate is connected to the controller to be taken to ensure that the load,battery,The polarity of the solar mobile panel and controller
five Before use:external temperature sensor probe into the left of the controller temperature probe interface probe positioned in same battery temperature(Line huge should be build-in devices of the exterior temperature probe coextensive Otherwise,the controller will control parameters of the temperature compensation of the error
6:In order to prevent accidents from occurring,install:non-professionals cannot be engaged in loading and unloading operations
Problem Solution:
No proper set up of solar panels cable polarity(“+””-”) Removing the polarity,you can re-install the correc
More than the rated energy of solar panels to lessen solar panel energy would not exceed the rated power controller discharge Problem Solution
Removing the weight is not wisely related to the load,re-install the proper
More than the rated load power to reduce load power,the controller would not exceed the rated power
Instantaneous starting current is too large,the battery means is too small,the alternative of high-capacity batteries,button troubleshooting
Wire Cable polarity unfastened or too sq. and expand retightening ambitious cable
All keys can troubleshoot faults,press 5 seconds to restore manufacturing facility settings