SmartGen HGM1790N
HGM1790N genset controller is go well with for unmarried unit automation and monitoring management (also can be utilized for pimping unit) It can be started and stopped manually or through a distant start/stop indicators HGM1790N controller can supervise and protect genset operation by way of collecting and examining genset records like generate voltage, current, water temperature, oil strain and so on, and graphical LCD monitor at the entrance panel displays fault situations and provides effective alarm alerts to be able to do upkeep as soon as possible Moreover, parameter threshold and postpone cost could be adjusted through entrance panel or USB port (communicated with PC software)
PERFORMANCE AND CHARACTERISTICS
Graphical LCD display(with backlight), LED indicator, touch-buttons operation;
Hard screen acrylic materials is used to guard display screen
Silicone panel and buttons are followed to increase high and coffee temperature adaption potential
Power supply vary DC (8~35)V,compatibility with 12V or 24V starter batteries;
Generator single part voltage, current, frequency, energy and load percentage parameters are measured and displayed:
Generator Voltage V Generator Frequency Hz
Generator Power kW Generator Current A
Load Percentage percent
Precision measured and displayed electrical number of generator:
Oil Pressure kPa Temperature ºC
Fuel Level % Total Running Time H (max 199999 hours)
Battery Voltage V Engine Speed RPM
Accumulated Start Times (max 199999 times, displayed on PC)
With genset fault defense and reveal purposes
3 working modes: manual, auto, stop;
Compatibility with multiple temperature, pressure, gasoline point sensors, which might be user-defined and used directly; temperature sensors, strain sensors can be used in parallel with annunciator, providing analog quantity and extending protection level on the similar time;
Multiple crank disconnect situations to choose (engine speed sensor, oil pressure, generator frequency);
1 configurable input port that are set as digital input or liquid point sensor;
4 constant relay outputs (fuel relay, beginning relay, stop relay and idle relay);
1 configurable output port which might be set as normal alarm output, fail to forestall output, preheat output or idle control output;
Parameters could be set and modified through users and stored in inside FLASH storage, because of this they won't be misplaced in case of strength off Most parameters of the controller would be modified utilizing the front panel and all parameters can be adjusted by way of PC application by way of type-B USB port;
Digital legislation of all parameters - instead of analog legislation using traditional potentiometer - and, therefore, increased reliability and stability;
Modular design, self extinguishing ABS plastic enclosure and embedded installation way; small size and compact structure with clean mounting