1000W 2000W Solar Panels Battery on Grid Tie Inverter Limiter for Home PV Power System DC 22-65V/45-90V AC 90V-130V 190V-260V
Why we produced the GRID TIE INVERTER WITH LIMITER ?
It is in response to the overwhelming clamor from our prospects for a product that can management the amount of strength that the grid tie inverters (GTI) can generate in order that the quantity of extra energy produced through the photo voltaic panels are lowered to insignificant levels, if no longer eliminated --- as a result of in some countries,the manufacturer can pay for the excess energy it gives to the distribution grid This is since the electric strength meters (the one offered through the electricity service in the area) aren't conscious of the route of strength flow In different words it only adds although strength is exported to the grid, thus, the patrons will be charged for energy although it's given to the grid, and here is the problem
This is the 2nd era grid tie inverter with limiter
With the 2d era GTIL,we integrated the restrict function contained in the GTI-We name this inner limiter this way,No extra limiter module is needed,reduced customer’s cost,more simpler for installation in case visitor install inverter far-off from the main circuit breaker,we also allow the 2d GTIL paintings with stand-alone limiter,we call this-external limiter sure,the inverter can work beneath regular Grid tie-no restrict mode,just set at the nice LCD and save your environment
New upgraded firmware enable battery or solar limiter recent and power model can set the maximum output energy of inverter , this will make the inverter work at cooler contition as person desire and increase the lifespan of the inverter can set kick in/off voltage of the inverter which may bendy utilizing with battery bank depend upon customers intellect and can stop battery bank from over discharged Data
INPUT DATA(DC)
SUN-1000G2-M/H
SUN-2000G2-H
Input Voltage Range
22-65VDC/45-90VDC
45-90VDC/60-110VDC
Maximum Input DC Voltage
65V/90V
90V/110V
Peak Power Tracking Voltage
25V-60V/50V-90V
50V-90V/65-110V
Operating DC Voltage Range
22V-65V
45V-90V/65-110V
Start-up Voltage
25V/49V
49V/65V
OUTPUT DATA(AC)
Maximum Output Power
1000W
2000W
Nominal Voltage
110VAC/230VAC
230VAC
Nominal Voltage Range
95-140V/185-265V
185-265V
Frequency Range
47 for
50gz,59 for 60hz
Power Factor
>0
Output Waveform
Pure Sine Wave
CHARACTERISTIC DATA
MPPT Effeciency
99%
Over Current Protection
Yes
Over Temperature Protection
Yes
Reverse Polarity Protection
Yes
Anit- Island Protection
Yes
Stackable
Just for AC
Output
Operating Temperature Range
-20℃~45℃
Storage Tmpeperature Range
-40℃~65℃
Current THD
<5%
Voltage THD
<5%
Standard
CE,EN50438
Efficiency
92%
Features
Net Weight
4
7
Gross Weight
five
8KG
Dimension(Package)
430*310*160mm
540*310*160mm
How to choose the inverter :
1 About enter voltage :
The 22-65V mannequin inverter will begin at 25V, after starting, the inverter can paintings in 22V-65V
Vmp 30v-60v Solar panels related in Parallel suggested, for instance : 4 pcs 200-260w (Vmp 31v solar panels in parallel )
the 45-90V mannequin inverter will begin at 49, after starting, the inverter can work in 45V-90V
Vmp 50v-90v Solar panels in parallel advised ; for Vmp 25V-45v photo voltaic panels , we recommend 2 panels in series , the full voltage might be 50V-90V , then connect 2 or more groups in parallel as an example : 2 pcs 200-260w (Vmp 31v ) linked in sequence , 2 groups in parallel Save 2 connectors
How to use the grid tie inverter ?
1 unit inverter set up / more items inverters in parallel the inverter AC output can be connected in the AC plug of grid in the home
2-1 Using Grid Tie Inverter With Limiter Model
2 The Grid Tie Inverter with Limiter delivers only the flexibility vital via the load and prevents turning in excess power hence avoids excess strength in going back to the Grid
2 The coronary heart of the Grid Tie Inverter with Limiter is the Limiter Module (LM) The LM consistently sampled the flexibility mandatory through the burden throughout the current sensor connected after the Main Circuit Breaker The LM then will activity the sign It then sends signal to Grid Tie Inverter how much strength to convey to the load in genuine time
2 The user, after installing and connecting the GTIL correctly, need not do anything and the unit will do its paintings automatically
three Installation of GTIL With Internal Limiter
3 This installation is not require an extra limiter module,Installation is far easier the present sensor cable to the new wire to measure the current,the inner limiter will auto locate the load power and control the inverter output power,excess strength can be effectively controlled
3 External protective gadget adding dc and ac SPD(Surge protection device),dc and ac breaker,etc is usually recommended to installed within the method
4 Setting on the LCD of the inverter:
The GTIL encompass 3 operating mode:
Work as normal GTI with out power limitation
Work below Internal limiter mode
Work beneath External limiter mode,
Pls make your atmosphere on the LCD and save it,details atmosphere operation,pls learn the GTI handbook
five Battery Discharge Power Mode
New upgraded firmware enable battery or solar limiter latest and tool mannequin
User can set the utmost output energy of inverter , this can make the inverter paintings at cooler contition as user favor and expand the lifespan of the inverter can set kick in/off voltage of the inverter which may bendy using with battery financial institution rely on users mind and might forestall battery financial institution from over discharged Limiter Module Specification
1 Clamp sensor- Max 100A
2 Wattmeter- Max 9999w
three Terminal Block-Max 20A
4 Receptacle- max 2000w
5 Clamp sensor signal- 5v AC max mA
6 DC sign Cable- 5v DC, max mA
Welcome for your go to and call, please contact me anytime when you have any query