Wir zeigen Dir Artikel, die nach United States geliefert werden. Um Artikel anzuzeigen, die in ein anderes Land geliefert werden, ändere bitte deine Lieferregion.
Liquid point control relays are regulators for conductive liquids that hold liquids within the limits between a most level and a minimal level and make sure the protection of submerged pumps opposed to dry operating It can be utilized in wells, tanks
Information:
– Power supply:①VG6112: 220V AC ②VG6012: 24V-240V AC/DC
– Frequency supply:50/60 Hz
– Operating temperature:-20℃~+55℃
– Storage temperature:-30℃~+70℃
– Setting accuracy-full range:±10%
– Contacts type:1 C/O (SPDT)
– Output ontacts:5A (Resistive Load)
– Output type:relay
– Dimenssion:90×18×65mm
VG6112: Water Supply
When the water level reaches E1, the pump stops automatically
When the water point drops below E2, the pump operates automatically
VG6112: Drain Off Water
When the water level reaches E1, the pump begins robotically
When the water point drops below E2, the pump stops robotically
VG6012: Control of two level & Control of one point
Water supply: When the water point reaches H&D(2 level: H, 1 level: D), the pump stops working When the water point drops under D, the postpone starts(in 1 level) When the time is up, the pump begins working and supplies water
Drain Off Water: When the water point reaches H&D(2 level: H, 1 level: D), the pump starts working and starts to drain When the water level drops below D, the postpone starts(in 1 level) When the time is up, the pump stops working and prevents draining
VG6112:
Power supply:220 VAC
Sensitivity Adjustable
VG6012:
Rated delivery voltage:24V-240V AC/DC
Function Adjustable: Pump up or down
Sensitivity Adjustable: 5-100 kΩ
Delay Adjustable: zero seconds
Liquid Level Sensor, Water Level Sensor
Material: Stainless Steel
Blue: 1
Yellow: 2m
Red: 2
Din Rail Mounted