Upgraded Hand held tiny Spectrum analyzer TinySA 2" reveal 100kHz to 960MHz with ESD protecedVersion V0
User interface:
* Display decision 320*240 pixels
* Screen diagonal 2"
* sixteen bits in line with RGB pixels
* Resistive touch control
* Jog change control
* USB serial port control
* Optional TTL USART port (SW no longer but implemented) on the internal PCB
* Linear energy supply to circumvent switching noise
*Add port ESD defense to improve version(V0)
The input/output specification of the tinySA is divided over the 4 modes
Low input mode spec:
* Input frequency differ from 100kHz to 350MHz
* Input impedance 50 ohm when enter attenuation set to 10dB or extra
* Selectable manual and automated enter attenuation between 0dB and 31dB in 1 dB steps
* Absolute maximum enter point with out attenuation of +10dBm
* Absolute most input energy with 30dB attenuation of +20dBm for short period
* Input Intercept Point of 1/3 order modulation products (IIP3) with 0dB attenuation of +15dBm
* 1dB compression point at +2dBm with 0dB attenuation
* Power detector decision of 0 and linearity versus frequency of +/-1dB
* Absolute strength level accuracy after energy point calibration of +/- 1dB
* Lowest discernible signal utilizing a decision bandwidth of 30kHz of -102dBm
* Frequency accuracy equivalent to the selected decision bandwidth
* Phase noise of -90dB/Hz at 100kHz offset and -115dB/Hz at 1MHz offset
* Spur loose dynamic range when utilizing a 30kHz decision bandwidth of 70dB
* Manually selectable decision filters of 3, 10, 30, 100, 300, 600kHz Automatic number of one of the 57 resolution filters
* On screen resolution of one hundred forty five or 290 measurement facets
* Scanning pace of over a thousand points/second utilizing greatest decision filters
* Automatic optimization of actual scanning aspects to guarantee policy of the whole scan range regardless of the selected decision bandwidth
* Spur suppression possibility for assessing if certain indicators are internally generated or truthfully present in the input sign
High input mode spec:
* Input frequency fluctuate from 240MHz to 960MHz
* As there is not any input bandfilter stable signals outdoors the 240MHz to 960MHz range may cause distortion of the in band indicators
* Absolute most input point without attenuation of +10dBm
* Input Intercept Point of 1/3 order modulation products (IIP3) of -5dBm
* 1dB compression point at -6dBm with 0dB attenuation
* Power detector resolution of zero and linearity as opposed to frequency of +/-1dB
* Absolute power point accuracy after strength level calibration of +/- 1dB
* Lowest discernible sign utilizing a decision bandwidth of 30kHz of -115dBm
* Frequency accuracy equal to the chosen resolution bandwidth
* Spur loose dynamic vary when utilizing a 30kHz decision bandwidth of 50dB
* Selectable (automatic and manual) resolution filters of 3, 10, 30, 100, three hundred and 600kHz
* Optional 25dB to 40dB frequency dependent input attenuator The energy level error with this attenuator activated increases to +/- 15dB
* On display screen resolution of one hundred forty five or 290 dimension facets
* Scanning speed of over one thousand points/second utilizing largest decision filters
* Automatic optimization of tangible scanning points to ensure policy of the entire scan fluctuate regardless of the selected decision bandwidth
Low output mode spec:
* Sinus output with harmonics under -40dB of primary
* Output frequency differ from 100kHz to 350MHz
* Output point selectable in 1dB steps between -76dBm and -6dBm
* Optional AM, slim FM and large FM modulation or slow sweep over selectable frequency span
High output mode spec:
* Square wave output
* Output frequency vary from 240MHz to 960MHz
* Output point selectable in variable increments between -38dBm and +13dBm
* Optional slim FM and broad FM modulation or gradual sweep over selectable frequency span
Reference generator spec:
* Optional square wave output with most important at -25dBm connected to excessive input/output
* Frequency would be set to 1MHz, 2MHz, 4MHz, 10MHz, 15MHz or 30MHz
Battery spec:
* Charging time max 1 hour on 500mA minimal USB port or USB charger
* Operation on entirely charged battery for not less than 2 hours
Package inclued:
TinySA 2" Spectrum analyzer *1
20cm sma-sma rg174 rf cabe *2
USB Type-C Data Cable *1
Hand rope *1
SMA feminine to female connector *1
SMA telescopic antenna *1