1 SummaryThis series controller is really good for Diesel / Gasoline / Gas Genset Start, Stop, Parameters monitoring, faults-checking in addition data surroundings 2 inch LCD display screen reveal with fresh UI design is adapted in this controller that the relative disasters can be displayed instantly All the parameters could be displayed by way of simulated indicators and words Besides, LCD screen can exhibit diversified faults in the similar time that the genset could be stopped once it can’t work
easily are Chinese/English interface options, extra language would be set according to user’s request All the parameters can be configured throughout the front face buttons or use programmable interface by way of RS485 or USB to regulate by way of PC It would be widely applied for every kind of car control formulation of gensets Main FeaturesThere are ten Models below DC4xS/C series: Used for unmarried mechanical device automation Start/Stop by way of distant birth signal: Based on DC40S, it adds RS485 port DC42S: Based on DC40S, it adds Mains tracking and AMF (Mains/Generator automated switching control), especially compatible for the automation formulation composed via mains and genset: Based on DC42S, it adds RS485 port
Dual core 32bit excessive functionality unmarried chip microcomputer
2 inch 240 * 128 high-resolution LCD screen, Available in 6 languages, user’s language set if mandatory
Indicator and number display by way of UI surface
Acrylic material is customized to protect the display screen
Silicone panels;
USB Port: parameters can be set even without energy via USB port to monitor in genuine time
With RS485 communique port, can obtain “Three Remote” functions through MODBUS protocol
Standard CAN communication port, integrated J1939 protocol, has matched more than forty kinds of engines;
Various kinds of parameters reveal DC4xS/C GENSET CONTROLLER USER MANUAL
Input/output function, fame could be shown directly
Real time clock inside: preset time function and auto maintenance is available Genset working plan can be set as a week or month
Maintenance countdown function, can set maintenance time or date
The black field function can save the relevant parameters of the unit when the fault alarm happens in genuine time, and it is convenient in finding the reason behind the fault
Totally 6relay’s output, amongst which four relay output could be self-configurable, each relay would be set as max 20 functions With four switches input, up to 20 functions optional;
3 sensor simulation enter connectors, the oil strain sensor is like minded with voltage signal input, and various display units would be configured
Battery charging control function,which can preserve the battery in step with battery voltage fame
Sensor could be self-defined by entrance face button or PC software Adapt to 3P4W,1P2W,2P3W(120V/240V,50/60HZ)
Various of crank conditions (RPM, Frequency, Oil Pressure) could be selected
Control Protection: Auto Start/Stop of genset, load transfer (ATS control) and perfect failure show and protection
Standard water-resistant rubber gasket The water-resistant can attain IP54
Module design: All the connections are tailored with European connectors so that installation, connection, fix and alternative could be more smoothly
three Parameters Display
Engine RPM
Engine oil stress
Engine temperature
Engine fuel level
Engine battery voltage
Charging voltage
CAN connected parameters(C sequence only)
Mains Frequency (only for DC42S/C)
Mains section voltage L-N (only for DC42S/C)
Mains section voltage L-L (only for DC42S/C)
Generator three Phase voltage L-N
Generator 3 Phase voltage L-L
Generator 3 part recent A
Generator Frequency Hz
Generator Power Factor COS φ
Generator energetic power KW
Generator obvious strength KVA
Generator reactive strength KVar
Real-time load price percent
Current load charge percent
Average loading charge percent
Current consumption KWH Total consumption KWH
Total Crank times
Cumulative strength on time of controller
Current working time
Total operating time
Maintenance notice
Switches input fame demonstrate
Output repute display of relays
Current date and time;
four Protection
Over speed
Under speed
Low oil strain
High temperature
Low fuel level
External emergency alarm
D+ open
RPM Lost Sensor Open
Over Frequency
Under Frequency
Over voltage
Under voltage
Over current
Non-balance of latest
Over energy
Maintenance expire
Low water point alarm
Emergency Stop
Crank failure
Battery over voltage
Battery beneath voltage
The charger fails to charge
Charger charging failure
Stop Failure
ECU alarm failure
ECU communication Failure