Tu tagad redzi preces, kas tiek piegādātas uz United States. Lai redzētu preces, kas tiek piegādas uz citām valstīm, izvēlies atbilstošu piegādes reģionu.














Daxtromn 4200W Hybrid Inverter 24V Pure Sine Wave Inverter 500VDC 140A MPPT Solar Charger 4 Hybrid Solar inverter with BMS Feature Of AGH-4 Hybrid Solar Inverter 1 Sine Wave Solar Inverter 2 120A MPPT Solar Charger three 500VDC PV Input four 2 Loads Output,Support BMS 5 PV enter voltage range(120~450VDC) 6 strength ingredient 1 7 Hybrid Solar inverter for 24V/48V formula 8 Module for easily connection 9 paintings with or with out battery 10 tracking & environment application 11 50hz or 60hz (program adjustable) 12 to use ac grid or generator strength thirteen anti-dusk kit for harsh environment 14 DC output for DC fan, LED bulb,router and so on What is 2AC out function? When there's no Main/AC IN/GRID INPUT ,and the battery less than the setted voltage main AC out will bring to an end automatically, the battery or pv solely provide strength for the second AC out To Guarantee your essential equipment continually working DO NOT CONNECT THE SECOND OUTPUT TO THE GRID,IT WILL DAMANGE YOUR INVERTER What is the BMS model? Difference between BMS and without BMS: If the battery has BMS, after plugging in the BMS, the inverter and the battery will speak and automatically regulate the charging voltage cut-off voltage and different parameters, and diverse parameters could be adjusted at any time in line with the condition of the battery, that will be a higher point for the life of the battery and the security of use The inverter and battery deserve to have BMS purposes on the similar time to communicate with one another Note:This is a wide voltage Hybrid Solar inverter, If Solar Inverter with out exterior battery ,The voltage which starts to connect with the solar panel must be above 150V for the inverter to paintings normally, if with external battery 120V is working NOT CONNECT THE SECOND OUTPUT TO THE GRID,IT WILL DAMANGE YOUR INVERTERAdvantage:Dual AC output: beneath ordinary conditions, the main circuit and secondary circuit outputs are used normally When there isn't any PV and mains power input and the battery voltage is too low, the major circuit is disconnected and only the secondary circuit output is retained to avoid wasting strength & AnswerQ:Whats the Rated output power ?A:Its 4200W for Model:AGH-4:Whats the max fee foreign money for battery ?A:Its 140AQ:Whats the MAX DC PV Input?A:Its 500VDCQ:How many AC output ports?A:2 lots ouputQ:What BMS protocols are supported?A:Most of them are supported, and we even have BMS protocols you can verify for compatibility yourself:How many volts of external battery use ?A:24V for Model :AGH-4:It can support Parallel ?A:No it is going to not supportQ:Whats the warranty?A:1 YearQ:If it has Wifi Model ?A:Yes Specification Of 4200W Hybrid Solar Inverter Model AGH-4 AGH-6 Phase 1-Phase Maximum PV Input Power 6200W 6500W Rated Output Power 4200W/4200VA 6200W/6200VA Maximum Solar Charging Current 120A GRID-TIE OPERATION PV Input(DC) Nominal DC Voltage/Maximum DC Voltage 360VDC/500VDC Start-up Voltage/Initial Feeding Voltage 90VDC/120VDC MPPT Voltage Range 90~450VDC Number of MPPT/Max Input Current 1/23A GRID OUTPUT(AC) Norminal Output Voltage 220/230/240VAC Output Valtage Range 195~253VAC Norminal Output Current 15 27 Power Factor >0 Feed-in Grid Frequency Range 49~51±1Hz EFFICIENCY Max Conversion Efficiency(Solar to AC) 98% TWO LOAD OUTPUT POWER(V2) Full Load 4200W 6200W Maximum Main Load 4200W 6200W Max Second Load(battery mode) 1200W 2067W Main Load Cut Off Voltage 22VDC 44VDC Main Load Return Voltage 26VDC 52VDC OFF-GRID OPERATION AC Input AC Start-up Voltage/Auto Restart Voltage 120-140VAC/180VAC Acceptable Input Voltage Range 90-280VAC or 170-280VAC Maximum AC Input Current 30A 40A Nominal operating frequency 50/60Hz Surge energy 7200W 12400W BATTERY MODE OUTPUT(AC) Nominal Output Voltage 220/230/240VAC Output Waveform Pure sine wave Efficiency(DC to AC) 94% BATTERY&CHARGER Nominal DC Voltage 24VDC 48VDC Maximum Solar Charging Current 120A Maximum AC Charging Current 100A PHYSICAL Dimension,D*W*H(mm) 110*334*423 Net Weight(Kgs) nine 10 INTERFACE Communication Port RS232/WIFI/RS485 ENVIRONMENT Operating Temperature -10~50℃







QWQER Express,
USPS,
DHL