







Açıklamalar
CONTEC MS200 Blood Pressure Simulation, followed Oscillometry NIBP Simulator dynamic BP This product is offered international If you employ it within the United States, please contact me earlier than procuring Introduction It is a multi - purpose test gadget for testing NIBP Monitor adopted Oscillometry Concise and chic in appearance, easy and convenient to operate, and it will generate the strain as much as 400mmHg (53 kPa) by the built-in air pump With the purposes of dynamic BP simulation under several conditions, static strain calibration, automatic leak verify and over-pressure reduction test, which can quickly and accurately analyze every single functionality of NIBP Monitor Functions 1)Pressure leak test2)Over-pressure relief check 3)BP simulation beneath common condition4)BP simulation under patient condition5)BP simulation beneath arrhythmia condition6)BP simulation under breathing interference condition7)BP simulation of neonate 8)Wrist BP simulation 9)User-defined BP simulation10)System setting function)The parameters set would be stored)ON/OFF operate 13)Dynamic BP simulation Performance BP simulation range: Systolic pressure: 2 kPa (20 mmHg) ~ forty kPa (300 mmHg)Diastolic pressure: 1 (10 mmHg) ~ 33 kPa (250mmHg)Pulse volume: 0 cc ~ 2 cc HR range: 30 bpm ~ 250 bpm; pulse volume > 2 cc, most HR: 200 bpmHR accuracy: ± 1 bpm (except patient condition, arrhythmia and breathing disturbance) Under patient condition:Weak pulse, tachycardia, obese, geriatric: ±(preset value 1%+1)bpmModerate exercise: ±(preset value 1%+1)bpmStrenuous exercise: ±(preset cost 3%+1)bpmPressure measurement:Range: 0kPa (0 mmHg) ~ fifty three kPa (400 mmHg)Resolution: 0 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0 psiAccuracy: zero kPa (0 mmHg) ~ 40 kPa (300 mmHg), ± (0 % of reading + 0) kPa or ± (0% of reading +1) mmHg40 kPa (301 mmHg) ~ 53 kPa (400mmHg), ± 2% of readingPressure leak testGenerate a stress up to four hundred mmHg via the integrated air pump It constantly exhibits the height pressure and the real-time pressure Leak fee is displayed after 10 seconds Over-pressure reduction testGenerate a pressure as much as 400 mmHg by the built-in air pump, it displays top strain source:Output range: 6 kPa (50 mmHg) ~ fifty three kPa(400 mmHg)Resolution: 0 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, zero psiDeviation between target pressure and actual pressure: ± 1 kPa (± 10 mmHg) in differ of thirteen kPa (100 mmHg) ~ 53 kPa (400 mmHg) with a minimum volume of 300 ccAirtightnessTotal airtightness: < 0 kPa/min (2 mmHg/min) below “OFF” stateAirtightness of built-in cuff: 0 kPa/min (2 mmHg/min)BP simulation preset price configuration desk BP simulation BP preset cost BP HR Pulse volumeStandard BP simulation 120/80(93) 80bpm 0 150/100(116) 0 200/150(166) 0 255/195(215) zero 60/30(40) zero 80/50(60) 0 100/65(76) 0 simulation below affected person conditionHealthy heart 120/80(93) 75bpm 0 Pulse 110/80(90) 95bpm 0 Exercise 140/90(106) 120bpm 1 Exer 140/90(106) 162bpm 1 120/80(93) 90bpm 0 150/110(123) 95bpm zero 120/105(110) 130bpm 0 120/60(80) 45bpm 1 simulation below arrhythmia conditionPremature Atrial Contraction1 138/53(81) 80bpm 0 Premature Atrial Contraction2 144/64(90) 83bpmPremature Ventricular Contraction 118/61(80) 83bpmAtrial Fibrillation and PVC 139/72(94) 91bpm BP simulation beneath respiratory interference conditionspontaneous breathing1 138/65(89) 104bpm 0 breathing2 149/65(93) 105bpmspontaneous breathing3 112/47(68) 86bpmcontrolled respiratory 132/44(73) 98bpmBP simulation of neonate 35/15(22) 120bpm zero 60/30(40) 0 80/50(60) 100/70(80)BP simulation of wrist cuff 120/80(93) 80bpm zero 160/100(120) 80/55(63)User-defined BP simulation[1] - - - -Note[1]:Support 9 user-defined BP simulation modes The following parameters can be explained via users:2 cost of diastolic strain needs to be less than systolic pressure, pulse volume and HR can't be set to the very best values (e, pulse volume ≤ 2, HR: 250 bpm; pulse volume > 2, HR: 200bpm) Accessories One User Manual Two fusesOne power twine Physical characteristic Display: 4" sixty five K colour LCD displayPower supply: AC100 ~ 240 V 50/60 Hz, <60 VAEnvironment temperature: + five ℃ ~ + 40 ℃Relative humidity: < ninety %, non-condensingAltitude: ≤ 3000 mAtmospheric pressure: 80 kPa ~ 106 kPaDimension: 207 (L) × 220 (W) × 121 (H) mmWeight: about 2 kg





Gözden geçirmek
0 people rated this product
CONTEC MS200 Blood Pressure Simulation, adopted Oscillometry NIBP Simulator dynamic BP


Ücretsiz kargo ve iade
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection