D52-2047 KWH Power wattmeter Electrical multi-function din rail meters power consumption meter ac200V-450V
Power intake
<0
Range of voltage
AC80-300V(singal phase) , AC200-450V(three phase)
Accuracy of voltage
1%+ 2digital
Range of latest
AC0-100A
Active power
0-30000W ( when the voltage AC80-300v)
0-45000W ( when the voltage AC200-450v)
Dimension
(w)54 x (H)80 x (D)64mm
Display
0"LED 9999 demonstrate in 3 line LED purple
Operating Temperature
-10°c~ 65°c
Humidity
20—80%
Weight
120g /pc
User Guide
D52-2047 DIN-rail multi-function Digital meter can measure AC voltage, AC current, energy factor, lively power, electric energy and electric calories of cumulative time
Technical Indicators
1 Accuracy: 1%±2 words
2 Mode: AC voltage and tool aspect use 4 purple led of 0
AC latest and electrical energy of cumulative time use five purple led of 0
Active power, electrical energy use 5 inexperienced led of zero
3: AC voltage : AC 80
AC Current : AC 0 Accuracy : 0
Active power: zero
Electric energy: 0
Electric calories of cumulative time: zero - 999
Power factor: 1
4: 2 instances in line with second
5: 54*80*64mm
6:Din-Rail
Application Method
1 the measuring voltage to the 1 and 2 terminal
2 of meter with inner recent transformer as graph 1 Make the twine through the gap within the meter and the path chose arbitrarily
3 of meter with external recent transformer as graph 2 Make the wire through the hole within the meter, and fasten the two wires of the secondary transformer to the 3 and 4 terminal
4 power on, the meter will display the measure results of the AC voltage (V), AC current (A) and lively strength (W)and the correlative red led will remove darkness from
5 press the button of SAM CK (on the correct of meter) down, the meter will substitute to display the measure results of strength element (cosΦ), electric calories of cumulative time (h) and electric energy (kwh) and the correlative purple led will remove darkness from
6 press the button of SAM CK down again, the meter will reveal the measure result of the AC voltage, AC recent and lively strength
7 When energy off, the meter can save the price of electrical calories and electrical calories of cumulative time, and move on cumulating data when the meter power-on next When the meter is exhibiting electric energy, you could possibly press down the button of SAM CK final for five seconds, then the electric energy and electric energy of cumulative time will to be zero and begin to cumulate when launch the button
Attention:
The meter can solely use to measure 50Hz AC city electricity, it will likely be destroyed when use to measure square wave, output of inverter or correction sine wave