







Açıklamalar
1 Display with LCD two columns,Can exhibit parameters straight ; 2 Trigger mode : high and low level,switch quantitymeet most of the needs three Power supply : 6-30V four Parameters would be modified Via UART five button to produce emergency stop function 6 5 minutes with none operation into a low-poweistate Any motion get up 7 OP / CL / LOP params can be modified separately 8 All parameters are robotically saved through power off In the OP/CL parameter modification interface,press the pause button presently to select the timing vary XXXX Timing range:1sec~9999sec XXX Timing range:0~999 XX Timing range:0~99 X Timing range:1min~999 For example,if you would like set the OP to 3 seconds,move the decimal point to ten digits LCD demonstrate 003 Parameter Description: OP on-time,CL off time,LOP cycle instances (1 - 9999 times,"----" represents a limiteless variety of cycles) l Parameter Settings: a) Press and keep the SET key to go into the environment interface; b) First set the working mode,work mode flashes reminder,set the operating mode by means of pressing the UP / DOWN keys; c) Short press the SET button to pick the working mode and enter the formulation parameter settings d) In the method parameter environment interface,press SET key to modify the formula parameters to be modified,and press / long press UP/DOWN key to switch (Note: Short press SET in P0~P3/ P8/P9 mode is invalid); e) In the OP/CL parameter amendment interface,short press STOP to change the timer unit (1s/0/0/1min); f) After all parameters are set,press and maintain the SET button for greater than 2 seconds to launch the hand,save the parameter settings and go out the surroundings interface Timing Range:0 sec~9999 min This product liquid crystal display display,very clear,simple and easy to use,powerful,but please learn user instructions carefully earlier than using Product Highlights: 1 Display with LCD two columns,Can show parameters directly; 2 Trigger mode: high and coffee level,switch quantity maximum of the needs 3 Power supply: 6~30V four Parameters can be changed by way of UART 5 Stop button to produce emergency stop operate 6 five minutes without any operation into a low-power state Any action wake up 7 OP/CL/LOP params could be modified individually eight All parameters are automatically stored by means of power off Working Mode Introduction(P1~P7) P0: After the sign is triggered,the relay conduction in OP time then disconnects; In the OP time,the signal is invalid P1: After the sign is triggered,the relay conduction in OP time then disconnects; In the OP time,the sign triggers a new timer P2: After the sign is triggered,the relay conduction in OP time then disconnects; In the OP time,signal trigger reset timer,relay disconnected and forestall timing P3: After the sign is triggered,the relay disconnects the CL time,and then the relay conduction P4: After the signal is triggered,the relay conduction the OP time,and then the relay disconnects the CL time,and then loops the above action,gives the signal again within the loop,relays disconnect,stops the timer; and the number of cycles (LOP) could be set; End of cycle,keep relay disconnected; P5: After the sign is triggered,the relay disconnects the CL time,and then the relay conduction the OP time,and then loops the above action,gives the signal back in the loop,relays conduction,stops the timer; and the variety of cycles (LOP) could be set; End of cycle,keep relay conduction; P6: No set off sign after power-on,After the relay conduction OP time,the relay disconnects the CL time,and then loops the above action,signal is invalid in the loop,the number of cycles (LOP) would be set; End of cycle,keep relay disconnected; P6: No set off sign after power-on,After the relay disconnects the CL time,the relay conduction OP time,and then loops the above action,signal is invalid within the loop,the number of cycles (LOP) can be set; End of cycle,keep relay conduction; P8: Signal preserve function: The signal is maintained,the timing is cleared,and the relay conduction; when the sign disappears,the relay disconnects after the timing OP; during the timing,there is one other signal and the timing is cleared; P9: Signal maintain function: The signal is maintained,the timing is cleared,and the relay disconnected; when the signal disappears,the relay conduction after the timing CL; during the timing,there is another signal and the timing is cleared; (P0~P7) mode,short press the pause button,Start timing if the formula is not timed; If the formulation is already timed,the formulation pauses the timer,the relay disconnected,flashing "out" to denote a reminder; P8/P9 mode,The pause button as a trigger sign in the Run interface,Short / Long press fail;






