United States ülkesine gönderilen ürünleri gösteriyoruz. Farklı bir ülkeye gönderilen ürünleri görmek için teslimat bölgenizi değiştirin.














the default shipping of this product is R1, if you want R2, R3 please depart a message when you place an order, thank you Note: The three-phase motor mushy delivery module can work for many years with out switching the contactor Selection: 20A for 2KW, 40A for 3-4KW, 60A for 5-6KW, 80A for 7-8KW, 100A for 8-10KW , 11-15KW with 150A, 20KW with 200A, the greater the motor power, the warmth sink must also be geared up with large, this product has been sold out thousands of pieces, only a few places motor isn't always appropriate Applicable place Can be extensively utilized in fans, pumps, belt conveyors, ball mills, conveyors and compressors and other a lot It is an ideal substitute product for replacing the ancient star/delta conversion, auto-coupling buck, magnetic management step-down, inverter and different step-down starting devices, secure and reliable Suitable for three phases: 380V, compatible: 50-60HZ Three-phase motor comfortable start module The tender birth time is adjustable for 30 seconds (time upward thrust refers to 0-380V) Starting voltage can be adjusted from 150V-250V to rated voltage (380V) There are two methods to apply it: 1 When the change is closed, the most important strength delivery is energized The gentle birth begins 2, use the swap to control, shut the gentle start, disconnect The comfortable beginning module now has three programs: 1 has tender delivery and no gentle quit 2 TSR-40WA-R2 has comfortable delivery and soft give up (how many V begins from how many V starts) 3 TSR-40WA-R3 has delicate start and delicate give up (soft quit to 0) Note: 1 No voltage could be applied to the swap 2, the default shipping of this product is R1, in order for you R2, R3 please depart a message once you place an order, thank you 3 Please use this radiator for this module Uses: pumps, fans, aerial vehicles, traditional motor gentle start, replace the gentle start of the inverter, update the smooth beginning of the celebrity triangle, etc, the wiring is tremendous simple, no use to connect the bypass contactor, powerful When the beginning potentiometer is midway up, it starts at 200V The smooth potentiometer lasts for a maximum of 30 seconds and corresponds to a full 380V For example: when the entire activity is adjusted to the minimum: the starting voltage is 150V and it takes zero seconds When the whole job is adjusted to half: birth 200V, soft birth time is ready 7 seconds When the whole task is adjusted to the maximum: the beginning voltage is 250V to 380V for 10 seconds Selection allowance is mostly recommended: TSR-10WA-R for 1KW, TSR-80WA-R for 8KW motor Radiator recommendation: radiator S1 beneath 4KW, radiator S1+F80 below 8KW, radiator DS1+F90 below 12KW, radiator S2-120+F120 under 20KW The following are the parameters of the three-phase motor mushy delivery module: Three-phase motor gentle start module features, new products 1 signal, it may be softened directly, tender beginning time (0-30 seconds) can be preset Starting voltage (150-250V) would be preset 2 output, can be used for three-phase star-delta connection 3 an appropriate radiator when using, and add compelled air cooling if essential 4 product is a multi-function strength integration module that encapsulates the key circuit of the thyristor and the part shift trigger management circuit five engineering plastic shell, copper base plate, hot temperature welding, strong brief overload means 6 use fan speed control, torque motor pace regulation, usual motor soft start, and many others Three-phase motor delicate delivery module product evaluation The three-phase delicate beginning module is a brand new form of included section shift voltage-regulating stable state relay independently evolved via our company It has enter and output photoelectric isolation, phase shift voltage regulator circuit and main circuit integrated, small size and light weight Long life, huge control power, stepless regulation, excessive insulation voltage, and so forth It can easily use the voltage replace of the input terminal to attain the automatic control of the burden strength at the output end, and the potentiometer can be utilized to manually alter the output power At an identical time, enter High impedance, internal synchronization, can be directly during the digital-to-analog converter and computer, digital program management circuit and device interface with 1~5V voltage, 0~10V voltage or 4~20mA latest output, can be used for three-phase electric voltage regulation, and The temperature control desk is hooked up to realize computerized temperature control, which isn't economical and reliable for the three-phase fan with low standards It is very handy to attain the stepless adjustment of the burden voltage power on the output finish The TRIAC output is mostly used for inductive load It is used in lighting fixtures adjustment of lights equipment, temperature management of heating in civil industry and pace management of motor Solid-state relay product selection considerations: ● When choosing the product, it is going to be selected consistent with the motor power, and it can be selected to the final election For example, 7 can be chosen to be bigger than 8KW) ● According to the relationship between load current and ambient temperature, when the ambient temperature is high or the warmth dissipation situation isn't always good, the present capacity needs to be elevated To stop short-circuit of the weight throughout use, it is required to attach the fast disconnect switch such as the product within the load circuit or Fast fuse ● For inductive load, connect the varistor on the output to forestall injury to the thyristor during overvoltage Optional varistor (MOV): 430-470V for 240V, 680-750V for 440V, 660V When selecting the file, prefer 1100-1200V ● When installing, it is required that the radiator and the touch surface of the product must be flat and smooth, and evenly coated with a layer of thermal grease on the floor Finally, the screws of the flat washing machine and the spring washer are screwed symmetrically ● When the forged state relay is shut down for the first time, tighten the fixing screws with the rest temperature to ensure that the solid state relay base plate and the surface of the warmth sink would be in shut contact to achieve the best heat dissipation impact ● The nominal recent of different kinds of strong state relays is the nominal recent when the ambient temperature is forty °C, so the warmth dissipation needs to be sufficient!! ● Pay attention to the weight end Do not use a multimeter to break the quality of the product Three-phase motor soft beginning module controller 4KW6KW8KW10KW12KW15KW20KW motor tender starter Three-phase motor gentle start module controller 4KW6KW8KW10KW12KW15KW20KW motor tender starter


















QWQER Express,
USPS,
DHL