MPPT Wind Solar Hybrid Charge Controller
Wind:0 - 11000W (11KW)
Solar:0 - 8000W (8KW)
12V 24V 48V Auto Match
Remote WiFi communication(Optional)
BIG POWER:
1 Controller Performancesummary
Thank you for selecting the BWS sequence Privilege Version Wind and Solar Hybrid photo voltaic charging controller This sequence of products adopts advanced high-speed processor and MARS Energy MPPT management algorithm to guarantee MPPT charging at low wind speed, featuring high reaction speed, high reliability and high indus- trial common points
The controller adopts color display design, the reveal news is more comprehensive, the exhibit interface is clearer, the controller supports WIFI module and GPRS module to broaden and implement APP cloud monitoring The controller is suitable for solar off-grid system, robotically controls charging and discharging, and may be applied In conversation base stations, family systems, road lighting fixtures techniques and subject monitoring and different fields
2 Product points
● The reveal adopts color display design, MARS Energy the show information is extra comprehensive, the exhibit interface is clearer, and the 4-key man-machine interface and operation surroundings are extra convenient;
●The MPPT management algorithm used for fan charging ensures MPPT charging at low wind velocity
●Fan three-stage charging mode:MPPT charging-lifting charging-floating charging
●Photovoltaic three-stage charging mode:CC fixed current-lifting charging-floating charging
●12V/24V battery formulation automatically recognizes, or 12V/24V/48V battery formula automatically acknowledges (Optional)
●RS485 communique can provide communique protocol to facitilate unified leadership and secondary development for customer
●The controller operating parameters could be seen and set through the cellular phone APP( Optional )
●The controller has complete defense applications comparable to overcharge, over discharge and overload;
● Lead-acid battery, ternary lithium battery, lithium iron phosphate, custom 4 battery kinds charging mode to choosing;(Battery Type)
●The controller has assorted load management modes, the burden has two outputs, and the output power and time can be set;
●The controller has broad adaptability, adaptive day and night;
1 Partial method parameter table
Model
5000W2525
6000W3030
8000W4040
9000W4545
13000W5080
15000W6090
19000W80110
System Rated Voltage
12V(9V-16VDC) / 24V(18V-32VDC) / 48V(42V-60VDC)
Solar Module
Voc
27(12V) / 55(24V) / 105V(48V)
Vmp
>Vbat+1V
Imp
138A(12V) 104A (24V) 52A (48V)
166A(12V) 125A (24V) 63A (48V)
222A(12V) 166A (24V) 83A (48V)
230A(12V) 188A (24V) 94A (48V)
230A(12V)
208A (24V)
104A (48V)
230A(12V) 230A (24V) 125A (48V)
230A(12V) 230A (24V) 160A (48V)
Workable Power
0W~2500W
0W~3000W
0W~4000W
0W~4500W
0W~5000W
0W~6000W
0W~8000W
Wind Turbine
Rated Voltage
12VAC(20)/ 24VAC (41)/ 48VAC(83)
Rated Current
138A(12V) 104A (24V) 52A (48V)
166A(12V) 125A (24V) 63A (48V)
222A(12V) 166A (24V) 83A (48V)
230A(12V) 188A (24V) 94A (48V)
230A(12V) 230A (24V) 160A (48V)
230A(12V) 230A (24V) 188A (48V)
230A(12V) 230A (24V) 230A (48V)
Workable Power
0W~2500W
0W~3000W
0W~4000W
0W~4500W
0W~8000W
0W~9000W
0W~11000W
Max Open circuit voltage
25(12VAC) / 51(24VAC) / 102(48VAC)
Special Note: The following are the optimum parameter settings, Suggest do not alter
Uunder
Over Discharge Voltage
10 / 21 / 43
Runder
Over Discharge Return
thirteen / 26 / fifty two
Uover
Over Charge Voltage
15 / 31 / sixty two
Rover
Over Charge Return
15 / 30 / 60
BCV
Increase Charge
14 / 28 / 57
Float
Floating Charge
thirteen / 27 / 55
Ufanbraking
Wind Breaking Voltage
25 / 51 / 102
DC Load output L1 & L2
Out Power
0W~1400W
0W~2800W
0W~5600W
Rated Voltage
12VDC
24VDC
48VDC
Rated Current
120A( in step with one 60A)
Battery Type
Lead-acid Battery , Gel Battery , LiFePO4 , Ternary lithium , and so forth
Operation Mode
Home use or Street light
Environment
Temperature
1) Working:-20℃~50℃; 2)Storage:-30℃~70℃
Humidity (°C)
10% ~ 90% No condensation
Protection Grade
IP30
2 Battery Parameter
Lead acid battery (single 12V)
System rated voltage / V
12V system (1 string)
24V formulation (2 strings)
48V system (4 strings)
12V default cost
Overvoltage (overcharge) / V
13~17V
26~34V
52~68V
15
Overvoltage return / V
13~17V
26~34V
52~68V
15V
Increase charging voltage / V
9~15V
18~30V
36~60V
14
Floating fee voltage / V
9~15V
18~30V
36~60V
thirteen
Undervoltage /V
7~13V
14~26V
28~52V
10
Undervoltage go back voltage /V
9~15V
18~30V
36~60V
thirteen
Ternary lithium battery (single section 3)
System rated voltage
12V formula (default 3 strings)
24V components (default 6 strings)
48V method (default 12 strings)
3 string defaults
Overvoltage (overcharge) / V
10~15V
21~30V
42~60V
13
Overvoltage go back / V
10~15V
21~30V
42~60V
12
Increase charging voltage / V
10~15V
21~30V
42~60V
12
Floating charge voltage / V
6~13
12~27V
24~54V
12
Undervoltage /V
6~13
12~27V
24~54V
nine
Undervoltage return voltage /V
6~13
12~27V
24~54V
10
Number of strings
3~4
6~8
14~18
three
Lithium iron phosphate (single section 3)
System rated voltage
12V components (default three strings)
24V system (default 6 strings)
48V components (default 12 strings)
4 string defaults
Overvoltage (overcharge) / V
9~12V
18~24V
36~48V
15
Overvoltage return / V
9~12V
18~24V
36~48V
14
Increase charging voltage / V
9~12V
18~24V
36~48V
14
Floating payment voltage / V
9~12V
18~24V
36~48V
13
Undervoltage /V
6~12V
12~24V
24~48V
11
Undervoltage return voltage /V
6~12V
12~24V
24~48V
12
Number of strings
3~4
6~8
14~18
4
About MPPT Start Voltage:
12V battery System, the wind generator votlage must arrive 8V
24V battery System, the wind generator voltage needs to arrive 16V
48v battery System, the wind generator voltage needs to arrive 32V
FAQ
1 desire MARS ENERGY as a provider of products?
(1) Mars Energy is known brand on the global market in new energy business We have strong R&D technical groups and professional production lines;
(2) Mars Energy is a manufacturer focusing on the manufacturing of controller from China It has a whole high quality leadership system and price management advantages;
(3) Mars Energy is a pacesetter in cross-border e-commerce After decades of operation, Mars Energy has completed the mixing of the provision chain ,Cheapest delivery cost Fastest to arrive around the world
(4) Mars Energy has established sales and after-sales teams in numerous countries, which can provide pre-sales steerage and after-sales service in a native language;
(5) Since becoming in 1999, Mars Energy has won praises from extra and more clients all over the world for its professionalism, guilty attitude and advantageous
2 to attach those 3 terminals of controller with my wind output wires?
(1) To AC wind turbine, anyone of 3 wires from wind turbine would be connected with any terminal of wind in your controller For they're non-electrode;
(2) To DC wind output is two wires(Positive Negative) , you can connect them with any wind terminals on your controller
three many connecting methods user can prefer when utilizing this controller?
For the wind charging and Solar charging are independent, so person can want anyone of the following because the connection method :
(1) Only connect wind turbine generator to payment battery;
(2) Only connect photo voltaic to charge battery;
(3) Connect wind turbine and photo voltaic to build a hybrid wind solar power method to price battery
four i solely join wind turbine as generator to price battery when i get my controller?
Yes, you might to do so But for the foremost objective of such controller designs for low energy intake equipment charging, such as: road lighting fixtures and tracking and many others So set up hybrid wind photo voltaic method can recuperate charging warrantly Because most of low-power wind turbine is installed in or near to the residential place, wind generation efficiency isn't excessive because of the low wind speed and short operating time
five to connect my system when I get this controller?
We strongly put forward person to install air swap between all DC and AC input or output Then please activate the breaker/ air change in this order:
(1) First activate the breaker between battery and controller;
(2) Second switch on the breaker between wind and controller;
(3) Third turn on the breaker between DC load and controller;
(4) Final switch on the breaker between Solar and controller
Remark: If you want to shut down the system, please continue in the opposite order as above
6 i need to install additional gentle conserving for my strength system?
Yes, it's best solution to set up further gentle maintaining
7 the controller to operate when the wind speed is too fast?
(1) For the output voltage or current from wind generator which beyond the safety range, the controller will robotically turn on the brake and progressively decelerate Meanwhile, the dump load will start to eat excess recent straight
(2) But when encountering strong storm weather, reminiscent of hurricane, typhoon, it is strongly recommended to place down the wind turbine directly
eight to design hybrid wind solar power formulation voltage, 12V, 24V, 48V, which one is healthier to me?
(1) The formula voltage is equivalent to the voltage of the battery pack;
(2) Once the battery voltage designed, the input voltage from wind turbine generator and solar modules must be matched in line with the specs in the parameter table;
(3) Therefore, customers can not easily suppose that extra lower voltage design, can get extra larger charging recent but forget about that the immoderate latest has exceeded the operating fluctuate of the controller or battery to wreck the controller or battery
nine designed in MPPT?
(1) Controller charging followed booster MPPT technology, which makes below low wind pace and occasional Voltage, the Wind turbine&;s electrical energy can still be used;
(2) In the high wind pace or the Wind turbine of energy is past the scope of the battery and load absorption, the controller instantly launched the step-less unloading function,protection formulation of the equipment
10 the wind generator is connected to the controller, why its operating speed turns into very slow immediately?
(1) The battery reaches the floating voltage;
(2) The rated output voltage of the wind generator is way greater than the battery, because the pace of the wind generator is proportional to the output voltage, and the voltage is dragged by way of the battery, so the speed might be very low;
11 wind generator sell off load when the controller displays small current?
The controller protect the all formula by means of detecting battery voltage, charging recent and temperature and so on When the battery reach floating fee voltage or excessive temperature, the wind generator will dump load, no matter how a lot charging latest it is
12 there showing no charging recent on LCD screen but the wind is working or the solar is working?
Only when the input voltage of solar panels or wind generator greater than battery then it would price the prerequisite is that the battery is correctly connected and never completely charged
thirteen the LCD would not mild up?
For the ability of controller comes from battery or solar when its operating So please verify solar enter or battery as follows
(1) The battery didn&;t join the controller well, please verify the battery and controller connection
(2) Battery is damaged, please examine and replace the battery;
(3) In nice sun day the photo voltaic enter is workable or not