Liquid point management relays are regulators for conductive liquids that preserve liquids within the limits between a most point and a minimum level and ensure the protection of submerged pumps opposed to dry working It can be used in wells, tanks
Information:
– Power supply:①VG6112: 220V AC ②VG6012: 24-240 AC/DC
– Frequency supply: 50/60 Hz
– Operating temperature:-20℃~+55℃
– Storage temperature:-30℃~+70℃
– Setting accuracy-full range:±10%
– Contacts type:1 C/O (SPDT)
– Output ontacts:5A/240 VAC,24 VDC (Resistive Load)
– Output type:relay
– Dimenssion:90×18×65mm
VG6112: Water Supply
When the water point reaches E1, the pump stops automatically
When the water level drops below E2, the pump operates robotically
VG6112: Drain Off Water
When the water point reaches E1, the pump starts robotically
When the water level drops beneath E2, the pump stops automatically
VG6012: Control of 2 point & Control of 1 point
Water supply: When the water level reaches H&D(2 level: H, 1 level: D), the pump stops operating When the water level drops beneath D, the put off starts(in 1 level) When the time is up, the pump starts working and supplies water
Drain Off Water: When the water point reaches H&D(2 level: H, 1 level: D), the pump begins working and begins to drain When the water point drops under D, the put off starts(in 1 level) When the time is up, the pump stops operating and prevents draining
VG6112:
Power supply:220 VAC
Sensitivity Adjustable
VG6012:
Rated delivery voltage:24-240 VAC/DC
Function Adjustable: Pump up or down
Sensitivity Adjustable: 5-100 kΩ
Delay Adjustable: zero seconds
Liquid Level Sensor, Water Level Sensor
Material: Stainless Steel
Blue: 1
Yellow: 2m
Red: 2
Din Rail Mounted