Micsig CP2100A CP2100B AC/DC Current Probes 2 10A/100A Maximum Measurable Current 100Apk 70 (DC+ACpk)
Safety Precautions
1 measuring circuit must be CAT II 600V or below ? Do not measure naked conductor
2 not contact the conductor below check and the sensor head while
measuring
three now not function in wet/damp situations
four not touch the software or the thing below check with moist fingers
five use this product within the scope authorised via the terminal
6 use this product as required ? Please floor the product throughout the USB strength cable
Specifications
Version :1
Modify content:First release
Release time:2019
Parameter:CP2100A /CP2100B
Bandwidth:DC~800KHz(CP2100A)/ DC~2(CP2100B)
Rise time: ≤583ns(CP2100A)/ ≤175ns(CP2100B)
Ranges :10A/100A(Optional at the switch)
Output sensitivity :0/A (10A) /0/A (100A)
DC accuarcy(typical) :3%±50mA (10A)/4%±50mA (100A,500mA~40Apk)
/15% (100A, 40Apk~100Apk)
Signal delay: <150ns (10A)/ <200ns (100A)
DC sign linearity (typical) :DC signal linearity, usual on web page 6
Measuring fluctuate :50mA~10Apk (10A)/1A~100Apk (100A)
Maximum measurable current:100Apk, 70 (DC+ACpk)/200Apk-pk, 70 (AC)
Maximum working voltage :CAT III 300V CAT II 600V
Maximum waft voltage :CAT III 300V CAT II 600V
Maximum conductor diameter:13mm
Overload indication :The buzzer beeping, the button mild flashing
Power supply :DC 5V
Probe head size: 11*6*2
Control box length :10*5*2
Length :228cm
Weight :290g
Single equipment weight: 1000g
Single kit size :29*23*5
Operating Temperature: 0°C ~50°C
Storage Temperature: -20°C ~80°C
Operating Humidity :5%~95% (0°C ~40°C, No condensation)
/5%~65% (40°C ~50°C, No condensation)
Operating Altitude :≤3000m
Storage Altitude: ≤12000m
User Instructions:
1 the BNC of the present probe to the oscilloscope (or other instrument) and fasten the USB cable to power the present probe
2 to the current, choose the suitable range at the probe, the corresponding button mild turns green
3 the oscilloscope settings: input impedance 1MΩ; Select recent or set exhibit unit as A; Set the probe attenuation multiplier of the corresponding channel If the probe is 100A(0/A), the oscilloscope ought to be 100X, if the probe is 10A(0/A), oscilloscope is 10X
four the automobile 0 button to achieve the automobile zero adjustment of the
probe After the zero adjustment is successful, the buzzer will beep for once Otherwise, the “beep” sound could be 3, indicating that the 0 adjustment fails; The external magnetic field can have a slight impact at the DC zero of the probe After the 0 adjustment is completed, please do not circulation it in a wide range
five Open the clamp of the present probe to clamp the conductor under check in step with the path indicated by the clamp head Note: If the measured current stream direction is contrary to the course indicated by means of the clamp head, the output is unfavourable
6 Adjust the oscilloscope to get the best waveform
Note: When the current exceeds the range, the buzzer will sound for many years and the button gentle will flash
Maintenance
1 the product warranty era and below common use, the corporate will be chargeable for unfastened maintenance due to failure of the product itself due to high quality disorders
2 keep the product as dry, clean and tidy
three there is dirt, use a gentle material or sponge with alcohol to take away grime
four now not use water
5 order to ensure the functionality of the product, it's endorsed to behavior an inspection or calibration once a year
Feature
1 CP2100 sequence is a current probe that may measure both DC and AC
2 is a split-type design that's small and exquisite
3 It makes use of a common BNC interface for oscilloscopes or a multi-connector for adapters
4 maximum recent that can be measured is 100Apk (70Arms); it's divided into 2 models, CP2100A measurable bandwidth range is DC~800KHz, CP2100B measurable bandwidth fluctuate is DC~2,The CP2100 series latest probe has two non-obligatory ranges: 10A and 100A
5 automated and manual 0 adjustment, USB strength supply, no extra energy supply, making measurement more handy 6 utilized in motor drive, power frequency, inverter, power supply, avionics and other fields