ANENG ST209 6000countsFull Intelligent Automatic Range Digital Current Multimeter(AUTO)
Feature
1-1 Display: liquid crystal show (LCD);
1-2 Maximum display: 5999 (3 5/6) bit computerized polarity display;
1-3 Measurement method: double integral A/D conversion;
1-4 Sampling rate: about three times consistent with second;
1-5 Overrange display: The absolute best function shows"OL";
1-6 Low voltage display:"Low voltage symbol "symbol appears;
1-7 Working environment:(0~40)°,relative humidity<80%;
1-8: AAA 1 battery(not incluida);
Function
DC voltage DCV
YES
AC voltage ACV
YES
DC recent DCA
YES
AC current ACA
YES
Resistor / Diode /
On-Off Test / Capacitor
YES
Frequency F
YES
Square wave output
YES
NCV
YES
Zero line /Fire line check
-
Full unit image
YES
Backlight manual/Auto off
YES
True RMS size
YES
Temperature(°/°)
YES
Flashlight lighting fixtures
YES
Range
Accuracy
Resolution
DC voltage
6V/60V/600V
± (0% + 10)
0/ 0/0
DC voltage
1000V
±(0%+3)
1V
AC voltage
6V/60V/600V
± (0% +3)
0/ 0/0
AC voltage
750V
± (1% +10)
1V
DC latest
60A/600A
± (2% +30)
0/0
AC current
60A/600A
± (2% +30)
0/0
Resistance (omh)
six hundred
± (0% + 5)
0
Resistance (omh)
6K/60K/600K/6M
± (0% + 3)
1/10/100/1k
Resistance (omh)
40M
± (2% + 3)
10k
Capacitance(C)
60nF/600nF/6uF/60uF/600uF
± (3% + 20)
10pF/100pF/1nF/10nF/100nF
Capacitance(C)
6mF/30mF
± (5% + 3)
1uF/10uF
Frequency
10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz
± (0% + 3)
0/0/1Hz/10Hz/100Hz/1kHz/10kHz
Temperature
(-20-1000℃)
As the directions
1℃
(0-1832℉)
As the directions
1℉
Package:
1* instruction manual,
1* certificate, one leather-based cas
1* pair of verify leads,
1* temperature probe,
NOTE:
This series of devices is designed according to IEC1010 (Safety Standards promulgated through the International Electrotechnical Commission), please read the safety precautions before use
1 When measuring voltage, please don't enter the restrict voltage exceeding the tremendous price of DC 1000V or AC 750V;
2 voltage below 2 is a safe voltage When measuring larger than 36V DC and 25V AC voltage, check whether or not the check leads are in reliable contact, are related correctly, and are effectively insulated to avoid electrical shock;
three When changing applications and ranges, the check leads should go away the check level