Technical Datas:
Product Name: Carbon fiber heating wireInsulating material: Silicone rubberMax enduring temperature: 200C degreesHeating temperature: in keeping with the using lengthHeating conductor: 12KLeakage current: 0/mThe product can stand up to max power: 25W/MDiameter: 3±0 MM ( Thicker and Safer; Толще и безопаснее )Colors: RedInfrared wavelength: 8UM-18UMConductor resistance: 33±10% Ω/m
Package Includes:
1 Buy 100m = 100m cable + 20 pcs copper tube + 20 pcs sleeves1 Buy 50m = 50m cable + 10 pcs copper tube + 10 pcs sleeves1 Buy 30m = 30m cable + 6 pcs copper tube + 6 pcs sleeves1 Buy 20m = 20m cable + 4 pcs copper tube + 4 pcs sleeves1 Buy 15m = 15m cable + four pcs copper tube + 4 pcs sleeves1 Buy 10m = 10m cable + 2 pcs copper tube + 2 pcs sleeves
How to calculate power?Voltage*Voltage÷resistance=electric power12K=33ohm/meter
For example, using 10m 12K carbon fiber cable on 220V, the flexibility is:220V*220V÷(10meters*33Ω)=150W
150w/10m=15w/m
For example, using15m 12K carbon fiber cable on 220V, the flexibility is:220V*220V÷(15meters*33Ω)=100W
100w/15m=6/m
The longer length, the smaller power, and decrease heating temperature is the ability of the cable? And what is heating temperature?1 The energy of the cable relies at the size that you just use, you can calculate the power in line with above examples Power = 5W/m, the temperature is about 30~40C degrees;Power = 10W/m, the temperature is set 40~50C degrees;Power = 15W/m, the temperature is set 50~60C degrees;Power = 20W/m, the temperature is ready 60~70C degrees;Power = 25W/m, the temperatuee is set 70~90C levels Please be aware that this is on your reference, now not exactly right because of varied examine circumstances
Product Images:
Heating Cable Connection:
Installation Suggestions:
Because of the feature of the carbon fiber cable, this cable can't be used for a protracted length For underfloor heating, we advise to use 10m according to piece, and attach all the things in parallel connections Keep the distance between cables 8~ 12cm
Questions and Answers:
Q1: What does "12K" mean? And what's the difference between 12K and 24K?A1: The "K" capacity one thousand, so 12K is 12 thousands, which means the conductor of 12K carbon fiber heating cable is mixed with 12000 pcs of carbon fiber, resistance is 33 Ohm/m The conductor of 24K cable is combined with 24000 pcs of carbon fiber, resistance is 17 Ohm/m: What is the adaptation between Rubber and Teflon jacket?A2: 1 the Rubber jacket is more flexible and thicker and could have some smell, and the scent will disappear after utilizing a number of days the Teflon jacket is a little challenging and thinner than rubber jacket, nevertheless it has no smell, and nice anti-corrosive function Related Room Thermostat - - - - >>