






说明
Features LCD screen with backlight can demonstrate operating time 0-100% velocity percentage! Comes with a wi-fi remote! Can set sluggish delivery slow give up time! Upper and decrease pace limits can be set! Can set the complete operating time Can set the running time and forestall time Repeated automated cycle start and prevent work! Can set the limit of automatic start and stop times! Jog acceleration and deceleration solved the problem of the ancient potentiometer smooth to break! Product parameters Input voltage: DC6 (the specific voltage needs to be equal to the rated voltage of the motor) Output voltage: linear beneath load Instantaneous current: 30A Continuous current: inside 20A Speed legislation type: flow law Speed adjustment method: Jog +- Wireless distant control: help Timing: Yes Slow birth sluggish stop: can be set Speed electronic display: 0-100 percentage table Speed range: 0-100% Control frequency: 15KHZ Connection type: Fence form terminal Support motor: brushed motor Module size: length * width * height 116mm * 76mm * 30mm Product internet weight: ninety five grams Panel opening: length * width 109mm * 70mm Installation method: embedded 1-2-3-4-5-6-7-8-9 operate settings are as follows Slow beginning time atmosphere Function 1: 000-100 Slow begin to one hundred pc velocity time adjustable between 0-10 seconds The default is 1 second Slow quit time setting Function 2: 000-100 Slow stop time is adjustable between 0-10 seconds The default is 1 moment Speed decrease limit surroundings Function 3: 000-080 The minimal velocity is adjustable between 0-80% and less than the maximum speed atmosphere price The default is zero Speed upper limit atmosphere Function 4: 000-100 The maximum pace is adjustable between 0-100% and is larger than the minimum pace setting cost The default is one hundred pc Acceleration / deceleration price atmosphere Function 5: 001 002 005 010 015 020 025 Each time the bottom line is pressed, the rate modifications through 1%, 2%, 5%, 10%, 15%, 20%, 25% Motor running time setting Function 6: 1 moment minimum-99 hours 59 minutes fifty nine seconds most The default is 99 hours 59 minutes 59 seconds Motor quit time atmosphere Function 7: 1 moment minimum-99 hours fifty nine mins 59 seconds most The default is ninety nine hours fifty nine minutes 59 seconds Number of motor start-stop cycles Function 8: adjustable from 1-999 times, default 999 occasions With or with out timing selection Function 9: 0 No 1 Yes Default 1 Yes Note: The input should be divided into wonderful and destructive The enter voltage needs to be equal to the rated voltage of the motor (within 6) For example, the rated voltage of the motor is 12V and the input voltage of the governor is 12V The rated voltage of the motor is 36V and the enter voltage of the governor is 36V Press and preserve the RUN / STOP key to turn the backlight on and rancid Slow delivery time surroundings Press the MENU key 1 to go into the operate 1 surroundings key surface Press the plus and minus keys to set the time Long press MENU to save and exit (10 is 1 moment and 100 is 10 seconds Slow stop time environment Press the MENU key 2 to enter the operate 2 atmosphere key floor Press the plus and minus keys to set the time Long press MENU to save lots of and go out (10 for 1 second and 100 for 10 seconds) Speed decrease limit environment Press MENU key three to enter function 3 key surface Press plus and minus key to set Long press MENU to save and go out Speed limit setting Press MENU key 4 to go into function four key surface Press plus and minus keys to set the dimensions price Long press MENU to save and exit Acceleration / deceleration value atmosphere Press MENU key five to go into function five key floor Press plus / minus key to modify Motor running time atmosphere Press the MENU key 6 to enter the function 6 key surface The default is the utmost time ninety nine hours fifty nine mins 59 seconds RUN / STOP key switching hours minutes seconds Press plus, minus, hour, minute, and moment and keep MENU to avoid wasting and go out Motor give up time environment Press the MENU key 7 to go into the operate 7 key floor The default is ninety nine hours, fifty nine minutes, and fifty nine seconds RUN / STOP key switching hours, minutes, and seconds Press plus, minus, hour, minute, and second and preserve MENU to save and exit Set the number of motor birth and prevent cycles Press the MENU key 8 instances to go into the operate 8 key surface The default is a most of 999 times With or without timing operate selection Press MENU key 9 to go into operate 9 key surface Default 1 has timing operate 0 No timing Press plus or minus key to switch Function 9: 0 is no timing operate screen





审核
0 people rated this product
12V 24V 36V 48V 30A PWM DC Motor Speed Controller Timing Remote Control LCD Smart Digital Display 0~100% Tachometer Adjustable
免费送货和退货
QWQER Express,
USPS,
DHL
购物安全
- 安全支付选项
- Secure privacy
- Secure logistics
- 交易保护
