我们向您展示运往United States的商品。要查看运往其他国家的商品,请更改您的配送地区。
I LS162 Transmission Meter Introduction LS162 transmission meter is a compact and small transmission meter that can simultaneously examine three parameters of light transmittance, ultraviolet rejection charge and infrared rejection rate It is acceptable for the display, exhibition, production, high quality inspection, inspection and other occasions The window movie transmission meter can verify the fabric optical houses such as car explosion-proof films, architectural movies and laminated glass The device has been extensively used in photo voltaic film manufacturers, automotive film distribution, automotive movie retail sales components LS162 transmission meter displayII LS162 Transmission Meter ApplicationLS162 photo voltaic film tester examine various materialsIII LS162 Transmission Meter Parameters UV height wavelength 365nm IR top wavelength 940nm Visible light 380nm-760nm full wavelength, in line with CIE photopic luminosity function Resolution 0% Measurement accuracy larger than ± 2% (colorless and uniform transparent material) Maximum pattern thickness <8mm Weight About 165 g (batteries excluded) Dimension 120mm × 25mm × 75mm Power delivery four AAA alkaline dry batteries LS162 photo voltaic film transmission meter appearanceIV LS162 Transmission Meter Characteristics 1 The window film transmission meter has clear-cut operation and the size is immediate Just put the measured object into the check slot then the visible gentle transmittance, ultraviolet and infrared rejection charge might be immediately displayed on the interface LS162 window tint meter test stick-film glass 2 The tool has small size and it's totally convenient to carry out; the check card slot is 8mm wide, which can directly test the car windshield LS162 transmission meter check vehicle side windshield 3 The instrument has an information lock function After the check is completed, press the HOLD button to fasten the verify records The records will remain at the reveal interface after removing the tested materials four LS162 portable photo voltaic film transmission meter has real-time dynamic calibration function When there is no examine object, the device will mechanically go back to the original information state to ensure more accurate test records LS162 window tint meter common reputation 5 The transmission meter is powered through four AAA alkaline dry batteries with ultra-low strength consumption And the software will robotically close down after three minutes without any operation With this design, the software is extra calories effective V LS162A Transmission Meter QualificationTransmission meter patent certificateVI LS162 Transmission Meter Operation Video VII LS162 Transmission Meter Packaging Details No Description Quantity Unit 1 LS162 Transmission Meter 1 pcs 2 AAA battery 4 pcs three User Manual 1 pcs four Certificate/warranty card 1 pcs 5 Packing box dimension 18*11*5 cm(L*W*H) 1 pcs LS162 transmission meter packageVIII LS162 Transmission Meter After-Sales Service The meter has one-year guarantee If the software works abnormally, please ship the whole instrument to our company for upkeep Provide customers with spare components and lifetime upkeep services Provide the users with the meter inspection service Free technical support for long term Manufacturer: Shenzhen Linshang Technology Co,Ltd Website: Service hotline: 0755-86263411 Email: sales21@linshangtech For additional information concerning the transmission meter selection, please click article under for particulars "Window Film Transmission Meter Selection and FAQ" IX FAQ about LS162 Transmission Meter1 The difference between LS162 (940nm) and LS162A (1400nm) window movie transmission meters The main difference between LS162 and LS162A is that the IR bands are assorted The infrared top wavelength of LS162 is 940nm and the LS162A is 1400nm These two bands are extra representative bands The absorbing film has a more in-depth infrared rejection effect at 940nm metal film (Insulation by way of reflection) has a more in-depth infrared rejection impact at 1400nm Please prefer the appropriate software in line with your personal film 2 The difference between LS162 and LS163 window film transmission meters LS162 measuring notch width is 8mm, LS163 measuring notch width is 6mm; LS162 use point gentle source, whereas LS163 use parallel mild path The latter has higher records accuracy when measuring thick materials; LS162 can only measure seen gentle transmittance, infrared and ultraviolet rejection rate, whereas LS163 can measure infrared and ultraviolet transmittance moreover those three data; LS163 has 3 demonstrate interfaces, the display screen can be circled in four directions and has a display screen backlight, yet LS162 doesn't 3 The difference between LS162 and LS101 window movie transmission meters LS162 use point light source, whereas LS101 use parallel mild route The latter has larger data accuracy for measuring thick materials; LS162 can only be powered by way of battery, while LS101 can be powered by way of USB cable moreover battery; LS101 has screen backlight, while LS162 has no screen backlight; Except for the above variations and the variations in appearance, the other parameters of LS101 and LS162 are completely a similar