







Beschreibung
Fertilizer Injector G1 G3/4 Male Thread 0%-4% Drip Irrigation Injector Dosing Pump Feature: 1 Water Powered Operating: The liquid doser dispenser operates utilizing water pressure to pressure the interior mechanism, permitting liquid components to be sucked in and dissolved into the water stream This revolutionary design guarantees effective and wonderful blending of fertilizers, enhancing plant nutrition 2 Erosion Proof Pump Body: The drip irrigation injector dosing pump body points an erosion proof design to preserve resolution feasibility and delay the general lifespan of the injector This robust construction guarantees constant functionality and reliability even in hard agricultural environments 3 Premium Housing: The ideal plastic housing of the automatic liquid dosing pump is abrasion proof, and resisting to aging, offering lengthy lasting durability and guard against the elements for extended use 4 Fine Dosing And Mixing Functions: The adjustable fertilizer injector gives complete dosing and mixing capabilities, including continual proportional injection, correct ratio tracking and adjustment, and automated uniform dilution These points facilitate correct and efficient fertilization, promoting optimum plant progress and fitness 5 User Friendly Design: The fertilizer injector is designed for ease of use with clean indicators, reminiscent of directional arrows indicating water flow, and easy to learn scales for automatic proportional dosing Users can very easily regulate dosage and fertilizer kinds without the need to adjust irrigation methods or management schemes, making operating simple, intuitive, and adaptable to various agricultural desires Specification: Item Type: Fertilizer Injector Material: Plastic Adapter: G1 to G3/4 Male Thread Main Machine Inlet Outlet Thread: G1 Male Thread Proportion Range: 0%-4% Flow Range: 10L/H-2500L/H Working Water Pressure: 0 Continuous Operation: >100T Water Temperature Range: 4-30℃ Main Application Areas: 1 Horticulture: Fertilization, storage, control for flowers, fruits, and greens 2 Livestock Farming: Fixed proportion fitness dosage for cattle and poultry (such as chickens, ducks, cattle, and pigs) three Industrial Field: Water treatment, industry, metal processing, hearth fighting, and so forth four Deodorizing solvents, cooling solvents, lubricating solvents and other particular solvents in constant percentage dilution five Car wash industry, printing industry, hospitals, wine industry and different industries I Dosing system doesn't pop out of the water reasons 1 the route of the water circulation is hooked up to the opposite, remove the tactic to correct the path of water consumption 2 the water pressure is too low, the doser can't start normally, eliminate the strategy of putting in a booster to extend water pressure II The doser does not suck the drug reasons for investigation 1 When the recent machine assembly, suction tube and mouth connection components can't leak, leakage will trigger the doser doesn't suction, or doser stop utilizing the liquid back to the barrel suction tube turns into empty, and liquid suction to the midway no longer sucked up These phenomena are installed suction tube isn't installed, air leakage attributable to (determine the leakage of a simple method: the dosage tube under the dosage gadget to a higher position than the dosage device, if the suction is normal, you could conclude that the suction tube is not installed, the interface leakage, remind: severe air leakage or water output is very small can not be used to determine the method) to forestall leakage of air would be installed in the suction tube, the outer facet of the mouth coated with a layer of spare parts, the sealing grease within the white box, the sealing grease within the kit When putting in the suction hose, observe a layer of sealing grease from the white box to the exterior of the nozzle, then insert the suction hose and tighten the suction hose solving nut 2 If used for a era of time, the doser paintings da da sound sluggish or no da da paintings sound, exclude methods: unscrew the cover, replace the motion on the two large sealing rings If the motion work sound normal, the doser would not suction or suction less phenomenon, you would unscrew the center black nut, the lower a part of the pump physique as a whole pulled down, update the drug rod above the small sealing rings, and follow particular sealing grease upkeep agent The small sealing rings on the lengthy rod of the movement ought to be changed continually and covered with upkeep agent, otherwise it will no longer suck the medication III Water into the barrel of the problem: cleansing the installation of the suction hose backside valve or replace the bottom valve (generally solely disassembled and flushed can be, hardly ever should update the bottom valve) Reason: the water again into the barrel is due to one manner valve there is something dirty, the loss of one way effect Flush clear at the line IV Leakage within the middle of the dosage dispenser treatment: use reliable instruments to unscrew the cover, the inside of the big sealing rings collated, put the proper to the dosage dispenser sealing rings groove inside, lined with just a little of the dosage dispenser comes with the maintenance agent, tighten it's no problem V Inlet and outlet seepage: dosage device installation problems, threaded material tape isn't always tied, non dosage device problems VI The liquid back into the key pipe: the installation of anti siphon valve The motive is that the pipeline branch design thickness and circulate distribution isn't always reasonable, not the pump problem, is a pipeline design issues Warning: the dosage should be used in the parameters of the water inlet to put in water filters and water pressure regulator valve, frequent switching of water inlet and outlet put in water hammer absorber More than the water discharge capacity of the doser, or a protracted period of time, high overwater work, the doser to increase the number of maintenance Water stress is better managed at 0 MPa, which can extend the provider life of the doser Liquid viscosity is large, must reduce the viscosity, in any other case it'll trigger the internal elements fracture It is forbidden to elongate the suction tube privately, the suction tube is simply too long will harm the motion Tips: plastic bag contained in the three seals are spare parts, save the spare, used for movement seals put on and tear replacement, white box material for the movement seals upkeep agent regularly covered in the motion seals above, cut put on and tear, develop the use of time Liquid concentration is illegitimate so as to add greater than the maximum price of the label, exceeding the traditional may cause the machine cannot work correctly or harm Special Reminder: the pump physique for a long time to resist water pressure or widespread switching of water attributable to the impact of water hammer will trigger plastic fatigue, power discount leakage cracking, to frequently examine the pump body shell whether or not there's injury or deformation, stumbled on that the problem or due to inspection of premature cracking to get replaced with spare parts This is to guarantee the conventional use of the basis of the mechanical device How to Use: Installation and Fixation: 1 The proportioning pump must be installed and used vertically with the pump body on top and the liquid suction pipe at the bottom It cannot work normally and will affect the lifespan if installed non vertically 2 Secure the proportioning pump to the wall or other facilities 3 Install the inlet and outlet of the proportioning pump according to the water flow direction marked on the pump body to ensure its air tightness Reversing the outlet direction will cause damage and stop operating 4 Install a 120 mesh filter between the water valve and the inlet of the proportioning pump 5 When the proportioning pump starts working normally, it will make a clicking sound, and the frequency will increase as the water output becomes faster Package List: 1 x Fertilizer Injector 1 x Wrench 2 x Adapters 6 x Accessory Rings 1 x Fixed Bracket 1 x Filter Tube with Instructions 1 x Manual Note: Prohibit Reverse Connection: Reverse path can not be used, the arrow is the path of the water Reminder: The pump physique for many years to face up to water strain or frequent switching of water caused by water hammer will trigger plastic fatigue, strength discount leakage cracking, we must usally examine the pump body casing whether or not there is damage or deformation, discovered that the difficulty or due to inspection of the premature cracking to get replaced parts This is to ensure the traditional use of the idea of the machine Make sure that the container for liquid components is not empty when utilizing the automatic proportional pump!2 Ensure that a filtration device is installed at the inlet end of the proportional pump throughout set up and use If there is a rise in working resistant throughout use, observe a distinct maintenance agent to the piston subject to increase its service life After use, the proportional pump should be cleaned with water to minimize erosion and lengthen the carrier lifetime of the proportional pump:The machine is used for a era of time would not suction or suction drug reduction, please replace the motion of the small sealing rings in a timely manner Spare parts package with equipment Pump installation should be far from the exposed energy supply, such as sockets, switches, etc, to forestall water leakage within the event of electrocution injury pump physique installation height to facilitate destiny upkeep operatiing shall prevail, leaving enough space for destiny upkeep operating





Rückmeldung
0 people rated this product
Fertilizer Injector G1 G3/4 Male Thread 0.4%-4% Drip Irrigation Injector Dosing Pump Automatic Liquid Dosing Pump
Kostenloser Versand & Rückversand
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection