Wir zeigen Dir Artikel, die nach United States geliefert werden. Um Artikel anzuzeigen, die in ein anderes Land geliefert werden, ändere bitte deine Lieferregion.
LC1D80M7C Main news Product collection TeSys Deca Product sequence TeSys Deca Product kind contactor Product short name LC1D Contactor utility discipline Applied to non inductive or micro inductive load, resistance furnace Applied to AC a lot with energy ingredient greater than or equal to 0 Category of use AC-4 AC-1 AC-3 AC-3e Number of poles 3P Rated operating voltage [Ue] Power delivery circuit: < = three hundred V DC 25 400 Hz Power delivery circuit: 660 V AC Rated working recent [Ie] eighty A 60 °C) at Up to = 440 V AC AC-3 Suitable for strength supply circuit 125 A 60 °C) at Up to = 440 V AC AC-1 Suitable for strength delivery circuit eighty A 60 °C) at Up to = 440 V AC AC-3E Suitable for strength delivery circuit [Uc] management circuit voltage 220 V AC 50/60 Hz Supplementary news Motor energy (kW) fifty five kW in Upper 500 V AC 50/60 Hz (AC-3) forty five kW in Upper 1000 V AC 50/60 Hz (AC-3) 22 kW in Upper 220/240 V AC 50/60 Hz (AC-3) 37 kW in Upper 380/400 V AC 50/60 Hz (AC-3) 45 kW in Upper 415/440 V AC 50/60 Hz (AC-3) 45 kW in Upper 660/690 V AC 50/60 Hz (AC-3) 15 kW in Upper four hundred V AC 50/60 Hz (AC-4) fifty five kW in Upper 500 V AC 50/60 Hz (AC-3E) 45 kW in Upper a thousand V AC 50/60 Hz (AC-3E) 22 kW in Upper 220/240 V AC 50/60 Hz (AC-3E) 37 kW in Upper 380/400 V AC 50/60 Hz (AC-3E) 45 kW in Upper 415/440 V AC 50/60 Hz (AC-3E) 45 kW in Upper 660/690 V AC 50/60 Hz (AC-3E) Model number LC1D Loop touch variety 3 NO Protective cover There isn't any Conventional heating latest [Ith] 10 A in Up to 60 °C for sign loops one hundred twenty five A is in Up to Power supply circuit for 60 °C Rated short-time withstand current [Icw] 640 A in Up to 40 ° C-10 s Suitable for power delivery circuit The 990 A is in Up to forty ° C-1 s Suitable for power delivery circuit a hundred thirty five A in Up to forty °C - 10 mins compatible for power circuit 320 A in Up to forty °C - 1 min for strength supply circuit a hundred A-1 s for sign loop 120 A-500 ms for signal circuits 140 A-100 ms for sign circuits A fuse to be used with a relay 10 A gG applicable sign loop complies with IEC 60947-5-1 200 A gG in Up to = 690 V with Type 1 relevant power supply circuit a hundred and sixty A gG in Up to = 690 V with Type 2 power supply circuit Average impedance 0Ω-Ith a hundred twenty five A 50 Hz Power delivery circuit Rated insulation voltage [Ui] Signal loop: 690 V in keeping with IEC 60947-1 Power delivery circuit: 690 V according to IEC 60947-4-1 Overvoltage category III Pollution point 3 Rated impulse face up to voltage [Uimp] 6 kV in response to IEC 60947 Safety and reliability ranking B10d = 1369863 contactors with nominal plenty comply with EN/ISO 13849-1 Contactors with B10d = 20000000 mechanical loads comply with EN/ISO 13849-1 Mechanical lifestyles four Mcycles Electrical lifestyles zero Mcycles one hundred twenty five A AC-1 Ue < = 440 V 1 Mcycles eighty A AC-3 Ue < = 440 V 2 Mcycles 48 A AC-3 Ue 660/690 V 1 Mcycles at eighty A AC-3e Ue < = 440 V 2 Mcycles 48 A AC-3e Ue 660/690 V Control loop attribute AC in On 50/60 Hz Surge suppression module No built-in surge suppression module Control voltage limit zero zero Uc-40 55 °C release 50/60 Hz zero 1 Uc-40 55 °C operating at 50 Hz 0 1 Uc-40 Run at 55 °C at 60 Hz (~50Hz) Power intake (VA) 245 VA 60 Hz 0 20 °C) 245 VA 50 Hz 0 20 °C) (~50Hz hold) Power Consumption (VA) 26 VA 50 Hz 0 20 °C) 26 VA 60 Hz 0 20 °C) Dissipation of heat 6 10 W in On 50/60 Hz Action time 20 35 ms closure 6 20 ms ruin Maximum working frequency 3600 times/hour at Up to 60 °C Wiring means Control loop: bolted 1 Fast loading cable selection: The soft cables don't contain a terminal Control loop: bolted 1 Fast loading of 2 mm² cable selection: Fast cables contain terminals Control loop: bolted 1 Fast loading cable type: There aren't any fast cables four mm² Cable selection: Fast cables do not involve terminals Power loop: Bus terminal Cable selection: Hard bus pass section: three x sixteen mm Power loop: Terminal four Fast loading cables do not contain terminals 50 mm² Outer diameter of the cable Ø: 17 mm Cable selection: Fast cables do not involve terminals Power loop: Terminal four Fast loading cables do not involve terminals 25 mm² Outer diameter of the cable Ø: 17 mm Cable selection: Fast cables do not contain terminals Power loop: Terminal four Fast loading cable terminals 50 mm² Outer diameter of the cable Ø: 17 mm Cable selection: Fast cables bring terminals Power loop: Terminal four Fast loading cable terminals sixteen mm² Outer diameter of the cable Ø: 17 mm Cable selection: Fast cables endure terminals Power loop: Terminal 4 Fast loading cables don't contain terminals 50 mm² Outer diameter of the cable Ø: 17 mm Cable selection: Fast cables don't involve terminals Power loop: Terminal four Fast loading cable selection: Fast cables do not involve terminals Tightening torque Control loop: 1 screwdriver Ø6 flat port for bolting Control loop: 1 screwdriver No 2 Phillips screws secured by way of bolts Power supply circuit: 12 N screwdriver through bolts Ø 6 8 mm a note Power delivery circuit: 12 N Tight hexagonal kind four mm with bolts Power delivery circuit: 12 N in the course of the terminal hexagonal 10 mm screw: M6 Power loop: 12 N by way of terminal with screwdriver Ø8 note Power supply circuit: 12 N Screwdriver pozidriv No 2 Control loop: 1 screwdriver pozidriv No 2 for bolting Auxiliary touch sort 1 NO + 1 NC Auxiliary contact variety Type Mechanical connection 1 NO + 1 NC consistent with IEC 60947-5-1 The type mirrors the repute of the main contact 1 NC complies with IEC 60947-4-1 Signal loop frequency 25 four hundred Hz Minimum switching current [Imin] five mA for signal loop Insulation resistance > 10 MΩ for sign loop No overlapping time 1 power loss between NC and NO contact 1 energy between NC and NO contact Installation mode Base mounting Rail mounting surroundings Standard GB 14048 IEC 60947-4-1 Product certification CCC CE UKCA IP defense level IP2X front panel leading loop applies according to screwed Protective measure TH complies with IEC 60068-2-30 Ambient air temperature - 40 Operating at 60 °C 60 70 °C with capacity reduction - 60 Storage at eighty °C Working altitude 3000 m None Fire resistance and resistance to irregular high temperature 850 °C complies with IEC 60695-2-11 Shock resistance and vibration resistance Seismic functionality contact open (2 gn (5 300 Hz)) based on IEC 60068-2-6 Impact resistance eleven ms contact open (8 gn) in line with IEC 60068-2-27 Impact resistance eleven ms contact closure (10 gn) in keeping with IEC 60068-2-27 Seismic performance Contact closed state (3 gn (5 three hundred Hz)) in accordance with IEC 60068-2-6 Altitude 127 mm breadth 85 mm profundity a hundred thirty mm Net weight 1