Wir zeigen Dir Artikel, die nach United States geliefert werden. Um Artikel anzuzeigen, die in ein anderes Land geliefert werden, ändere bitte deine Lieferregion.
Features
■ Compact Design
■ Overload / Phase Loss / Locked Rotor
Protection
■ Independently Adjustable Starting Trip Delay &
Operating Time
■ Wide Current Range:0~600A
■ Wide Operating Voltage Range
■ PWR & Trip Indication LED
■ Manual / Electric Reset
■ Ambient Insensitive
■ Low Energy Consumption
■(No Volt Release/Fail-safe Operation)→N Type
※Single-phase, three-phase out there (No Volt Release/Fail-safe Operation)→N
Used for
- Low Voltage Induced Electromotor (600V Level)
Protective Relay
- Break-Down Watch Current Relay
- Alternative Replacement for the Existing Relay
Protetcion
Protective Item Operating (Trip) Time
Over-Current = O-TIME
Phase Loss = O-TIME
Locked Rotor = D-TIME+O-TIME
LED
Ammeter Function:
After the motor runs smoothly, flip the overcurrent atmosphere knob slowly counter clockwise to the pink indicator light, which is 100 percent of the actual operating recent And then flip the knob clockwise to just turn off the red light at this level for the particular working latest cost of about 103%
Run / Operation Indicator:
Relay Trip: Red LED
Power / ordinary working status: Green LED
Manual / Electric Reset
With test button ehld down,the pink LED is on and the product will day out after O-TIME
The relay may be de-energized when RESET button is driven or the control power is disconnected
Set
After the set up is whole the settings as follows
Set knob: D-TIME(Delay Time) Set two to three seconds longer than the motor starting time
Set knob: O-TIME(Over-current run time) Set lower than the motor&;s persistence time with over-current
Set knob: Load(Rated Current) Set over 110% of the motor&;s rated latest of beneath 120% of its working latest
TEST Instruction
With check button held down,the orange LED is on and the product will day out after O-TIME
The relay will be de-energized when RESET button is driven or the management energy is disconnected
LED Indication
Item PWR(Green)LED Trip(Red)LED
Power ○ ×
Normal Running ○ ×
Trip × ○
Specifications
Current Range : Type05) zero
Type30) 3-35A
Type60) 5-70A
Type600) Use an exterior
CT(secondary 5A)over 60A with 05 type
Operating Voltage(Un): 12VAC/DC, 24VAC/DC, 110VAC, 90~260VAC, 180~460VAC
Operating Frequency: 50/60Hz
Operating Power: <2W
Operating Temperature: -20℃·····+55℃
Waiting(t): D-Time 0, O-Time 0
Asymmetry Set: %±10
Contact: 5A 250VAC Resistive Load
Mounting: 35mm Din Rail(D) or Pane(P)
Dimensions
Construction
Connection Diagram