







Beschreibung
3-liter tank: inner diameter 18cm, inner peak 12 cm. 4-liter tank: inner diameter 20cm, internal peak 13 cm. 6-liter tank: inside diameter 22cm, internal height 16cm. 8-liter tank: inside diameter 24cm, inside peak 18 cm. The product incorporates a seal, pluggable hoses and connectors, and a number of units of spare sealing plug are sent. Among them, hot temperature resistant silicone sealing plug can be used when the tank physique is heated. Elastic silica gel hosepipe inside and outer diameter is 4x7mm, or 5x8mm. The tank body is made of food grade 304 stainless steel, which are safely contacted with food. The lid is a clear borosilicate arched glass cover. The lid and tank body are warmth resistant and warmth resistant, high adverse strain (over-100kpa), and may be externally linked with high-power commercial grade vacuum machine. Our vacuum electric pumpIt is appropriate for low-viscosity slow-drying colloidal foam removal. For example, it may be used for epoxy defoaming. If it is used for silica gel defoaming, the hardness is 20 levels or less. After many operations, the air is pumped and then deflated, which has a undeniable effect. If it is used to remove bubbles from high-hardness and quick-drying silica gel, we promote that you simply buy a machine with a excessive power of vacuum mechanical device and a detrimental pressure of at least-95Kpa, or a suction of at the very least 2 liters consistent with second. The small electric suction pump equipped in our shop makes use of the enter 110~220V AC, the output 12V DC 2 ~ 3A, the destructive stress is about-80 ~ Kpa, and the actual accessible damaging stress is about-60 ~ Kpa.Another suction vacuum pump in our shop makes use of 220V AC, unfavorable pressure is about-80 ~ Kpa, and the actual adverse strain in the tank is about-70 ~ Kpa. There are different vacuum pumps in our shop from time to time. Welcome to buy. It is suggested that the air extraction time should be 1 to 2 mins whenever for defoaming. After the air extraction, the lower joint could be automatically vacuum maintained and the joint can be pulled out at any time during the air extraction process. Items would be saved in vacuum for a long time for a number of days to several months. The vacuum retaining time mainly is dependent upon the vacuum adverse strain within the tank and whether the contents are highly volatile. Lids and cans can be utilized as normal kitchenware,This allows you to maintain the worth of your investment and give away the lid manage from time to time. The above mannequin is small and economical electrical pump, suitableThe 3-liter tank in our shop is used for pumping, electrical pump of its own adverse pressure is-80Kpa, and the particular maximum adverse pressure within the tank shows about-60kpa. This pump would not have a warmth dissipation device. Generally, the pumping time is recommended to be 2 minutes. Long-time operation will overheat and Crash (generally get better after cooling), or make plastic elements deform, affecting product performance. The above is the pump changed by way of the previous compressor, which is sent randomly in diversified styles. The pump body is very likely to have rust and scratches, and it smells a little when running. It can be used for pumping and inflating. This pump is terribly heavy, about 4 ~ kg. The following electric pump is simple to operate (can solely pump),The damaging pressure is about-80 ~ Kpa, and the particular damaging strain in the tank is about-70 ~ Kpa,Electric pump exquisite workmanship, low noise and rapid air extraction, with its own swap and oil-water separator. 1. The following is a likely pumping scheme. Use straight forward room temperatureSealing plug and white suction interface, easy to operate and brief to pump, sealing plug can be straight put on the lid hole. 2. The following is the solution of high temperature resistant silica gel sealing plug, which is tightly put in and not clean to fall. The Blue sealing plug must be matched with the golf green suction connector. Reminder: 1) before pumping, ensure that the rubber gasket is flat with the lower aircraft of the glass cover. You can use your arms to flatten the rubber gasket alongside the outer periphery of the glass cover. The photo above shows the impact picture of rubber gasket when the canopy is viewed in reverse. 2) when pumping, gently hold the suction connector together with your hand for about a seconds, and the encircling of the lid would be pressed a few times for speedy pressure. 3) vacuum meter could be directly put into the barrel to immediately hit upon the unfavourable pressure value. After being acquainted with the destructive stress situation, you can not put vacuum meter. 4) Please handle the arched glass hide gently throughout use. The cover is pressure-resistant and shatter-resistant. 5) it may be deflated by touching sealing plug. Rapid deflating may lead to colloid splashing within the tank. Vacuum meter pay attention to dwell away. 6) the impact could be effectively stepped forward after multiple pumping, and the pumping time is usually recommended to be 1 to two mins each time, After power failure, it's robotically sealed and stored in pressure, so there isn't any want for continual pumping. 7) straight forward kind small electric pump cannot run for a protracted time, otherwise it could trigger overheating and crash, or impact performance. 8) newbie customers suggest utilizing small cup to habits a small quantity of experiments first. 9) please clean the tank and lid in time earlier than curing the glue. It is recommended to pad a bit of paper at the backside of the tank for straightforward cleansing of dirt.





Rückmeldung
0 people rated this product
Stainless Steel Vacuum Tank Electric Vacuum Sealed Tank with Transparent Glass Cover Epoxy Glue Bubble Removing Barrel
Kostenloser Versand & Rückversand
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection
