Buydo.com: Online Shopping for Jewelry, Sports, Toys, Beauty, Mobile & more

Skip to main content Welcome to Buydo. Check our Special Deals - up to 80% off.
1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V

Description

  • This product has the following characteristics: 1 Implement high-frequency immediate and widespread on/off of the circuit 2 The on-off job won't generate noise 3 There isn't any electric spark four There will be no electromagnetic interference 5 The service lifestyles is longer than that of commonly used electromagnetic relays It can completely replace electromagnetic relays Often used to manage motors, LED light strips, DC motors, micro water pumps, solenoid valves, etc 1: Product model: YF-11 with 32 generally used functions to meet more application needs; Capable of controlling electromagnetic valves, water pumps, motors, mild strips, and so on to operate freely 2: Input voltage: DC 7~24V universal; Please leave a word if different operating voltages are required 3: Output power: able to controlling DC loads as much as 10A 4: Time range: zero seconds to 999 minutes, adjustable at any time 5: Wiring port description: 1 DC+: Input DC strength delivery superb pole 2 DC -: Input DC energy damaging pole 3 IN+: Positive pole of signal enter terminal 4 IN -: Signal enter terminal detrimental pole 5 OUT+: output advantageous pole 6 OUT -: Output negative pole Button triggering: (Positive pole triggering: DC - and in - are quick circuited, and DC+and in+are related to the button) Or: (Negative trigger: DC+and in+are short circuited, and DC - and in - are related to the button) 6: Function List: P-11: Jog (signal output starts, sign disappears, output stops) P-12: Self locking (start with one sign output and forestall with another signal output) P-13: Signal is given, and the output starts and mechanically stops inside A seconds; Invalid triggering throughout delay era P-14: Give a signal, output to start and routinely stop within A seconds; Trigger a retiming during the put off period P-15: Signal is given, and the output starts and routinely stops inside A seconds; Trigger stacking timing during delay era P-16: Signal is given, and the output begins and robotically stops inside A seconds; Trigger reset throughout delay period P-17: Signal is given, output is activated, input signal is disconnected, timing begins for A seconds, energy is minimize off, and signal is given back to maintain output during the delay period, timing stops P-18: After power on, the output starts, and the power is bring to an end after a put off of A seconds; Until subsequent strength on P-21: Signal is given, and after a delay of A seconds, the output starts P-22: Signal is given, after exceeding A seconds, the output starts, the signal disappears, and the output stops P-23: After the sign disappears for more than A seconds, the output starts If there is a signal, the output stops P-24: After a sign exceeds A seconds, the output starts, and after the sign disappears for more than A seconds, the output stops P-25: After a signal exceeds A seconds, the output starts, and after one other signal exceeds A seconds, the output stops P-26: If there is a sign output, beginning and prevent A seconds later If the sign disappears, beginning back A seconds later and the output stops P-27: Detect pulse signal, output stops; No pulse signal, output starts after A seconds; (If the signal continues or disappears, it's considered as no pulse signal) P-28: After powering on, after a delay of A seconds, the output starts till energy is bring to a halt P-31: After energy on, the output begins for A seconds, stops for B seconds, and cycles infinitely; Power outage give up P-32: There is a signal, birth P-31 limitless cycle; Signal disappears, terminating cycle P-33: Give a signal to start P-31 infinite loop; Give another sign to terminate the loop P-34: After power on, after a postpone of A seconds, the output starts and stops after B seconds of suction P-35: There is a sign After a put off of A seconds, the output begins and forestalls after B seconds of suction P-36: There is a signal, after exceeding A seconds, the output starts, stops after B seconds of suction, the signal disappears, and the timing clears and prevents P-37: If there is a signal, the output will delivery for A seconds and robotically stop After stopping, it will likely be timed for B seconds The sign trigger can be invalid inside A+B time P-38: If there's a signal, the output will delivery for A seconds and mechanically stop After preventing for an additional B seconds, the output will delivery again for A seconds and automatically give up P-41: No action when there is a signal; Signal disappearance trigger; Disconnect after output start put off A time P-42: The signal disappears, and after a postpone of A time, the output starts; End of work B time P-43: After the signal disappears for greater than A time, the output starts; End of labor B time P-44: After power on, output the beginning A time and forestall B time; Cycle C automatically stops P-45: No action when powered on, after giving a signal; Output delivery A time and stop B time; Automatic stop of cycle C; Give the signal again, execute it again P-46: When the signal exceeds A times, the output starts; Maintain output; Power outage quit P-47: After giving the sign more than A times, the output starts and stops in B seconds P-48: Within C seconds, after continuously providing indicators for more than A times, the output begins and forestalls in B seconds 7: Key surroundings instructions: When powered on, the demonstrate "- - -" indicates getting into standby mode; Press K1 for the first time, (it takes more than 1 moment to be positive to prevent false triggering) display: P - 11: K2 adjustment holotype, K3K4 adjustment function Press K1 for the second time, and the screen displays: A001: K2 and K3 adjust the first time A, K4 modify the decimal point (time unit) Press K1 for the 0.33 time, and the screen displays: B001: K2 and K3 adjust the second time B, K4 modify the decimal level (time unit) Press K1 for the fourth time and exhibit "-- --" to go into standby mode Press K4 in standby mode to completely flip off/on the exhibit and switch to low power mode 8: Description of decimal time units: X XX decimal level to the hundredth place, timing range: zero seconds to nine seconds XX X decimal level to the 10th place, timing range: 0 seconds to ninety nine seconds XXX has no decimal point, timing range: 1 second to 999 seconds XXX Decimal point in a single place, timing range: 1 minute to 999 mins

  • 1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
  • 1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
  • 1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
  • 1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V
  • 1 CH Trigger Cycle Time Delay Relay DC 7-24V Mosfet Switch Module Timer Timing Relay for LED Light Motor Pump 12V 24V

Review

0 people rated this product
No reviews