







Description
MPPT Wind Solar Hybrid Charge Controller Wind:0 - 9000W (9KW) Solar:0 - 6000W (6KW) 12V 24V 48V Auto Match Remote WiFi communication(Optional) Product Description: Product Introduction: This model is particular designed for hybrid wind solar energy components charge for street lamp, monitoring Home system, energy station and many others formulation And it's workable for Lithium , GEL, Lead-acid battery with complete charge and discharge defense Large length LCD display is handy for parameter(from solar, wind and battery) query and adjustment yet low strength consumption It could be flexibly installed in cruise ships, RVs, and land indoors Powerful applications and lightweight size but excellent warmth dissipation are its excellent features Perfect Protection: Solar Reversed Charging protection,Battery open circuit protection、battery anti-reverse connection protection protection、Over latest and over voltage auto brake protection、Over load protection,etc High performance and stable chip control; Automatically tournament with 12V/24V/48V auto match sealed battery voltage; Workable for battery: Supports any variety of battery( eg: 1 lead-acid cell / 2 Gel battery / 3 LiFePo4 / 4Ternary lithium / 5 custom); LCD exhibits voltage and latest of wind, solar and load parameter; The inner circuit board of the controller is sprayed to stop dust, moisture and static electrical energy Wind adopts MPPT increase charging; exterior dump-load resistance, intelligent disconnection of Solar charging Product Parameter: 1 Partial formulation parameter desk Model 4000W2020 6000W3030 7000W3535 8000W4040 9000W4545 13000W5080 15000W6090 System Rated Voltage 12V(9V-16VDC) / 24V(18V-32VDC) / 48V(42V-60VDC) Solar Module Voc 27(12V) / 55(24V) / 105V(48V) Vmp >Vbat+1V Imp 112A(12V) 84A (24V) 42A (48V) 166A(12V) 125A (24V) 63A (48V) 190A(12V) 146A (24V) 73A (48V) 190A(12V) 166A (24V) 84A (48V) 190A(12V) 190A (24V) 94A (48V) 190A(12V) 190A (24V) 105A (48V) 190A(12V) 190A (24V) 125A (48V) Workable Power 0W~2000W 0W~3000W 0W~3500W 0W~4000W 0W~4500W 0W~5000W 0W~6000W Wind Turbine Rated Voltage 12VAC(20)/ 24VAC (41)/ 48VAC(83) Rated Current 112A(12V) 84A (24V) 42A (48V) 166A(12V) 125A (24V) 63A (48V) 190A(12V) 146A (24V) 73A (48V) 190A(12V) 166A (24V) 84A (48V) 190A(12V) 190A (24V) 94A (48V) 190A(12V) 190A (24V) 166A (48V) 190A(12V) 190A (24V) 190A (48V) Workable Power 0W~2000W 0W~3000W 0W~3500W 0W~4000W 0W~4500W 0W~8000W 0W~9000W Max Open circuit voltage 25(12VAC) / 51(24VAC) / 102(48VAC) Special Note: The following are the optimal parameter settings, Suggest don't modify Uunder Over Discharge Voltage 10 / 21 / forty three Runder Over Discharge Return thirteen / 26 / fifty two Uover Over Charge Voltage 15 / 31 / 62 Rover Over Charge Return 15 / 30 / 60 BCV Increase Charge 14 / 28 / 57 Float Floating Charge thirteen / 27 / 55 Ufanbraking Wind Breaking Voltage 25 / 51 / 102 DC Load output L1 & L2 Out Power 0W~180W (Per one-way) 0W~700W (Per one-way) 0W~1400W (Per one-way) Rated Voltage 12VDC 24VDC 48VDC Current Max Max 60A (per a method " L+ L1- " or " L+ L2- " Max 30A ) Battery Type Lead-acid Battery , Gel Battery , LiFePO4 , Ternary lithium , and so on Operation Mode Home use or Street light Environment Temperature 1) Working:-20℃~50℃; 2)Storage:-30℃~70℃ Humidity (°C) 10% ~ 90% No condensation Protection Grade IP30 2 Battery Parameter Lead acid battery (single 12V) System rated voltage / V 12V formulation (1 string) 24V formula (2 strings) 48V components (4 strings) 12V default value Overvoltage (overcharge) / V 13~17V 26~34V 52~68V 15 Overvoltage go back / V 13~17V 26~34V 52~68V 15V Increase charging voltage / V 9~15V 18~30V 36~60V 14 Floating fee voltage / V 9~15V 18~30V 36~60V 13 Undervoltage /V 7~13V 14~26V 28~52V 10 Undervoltage return voltage /V 9~15V 18~30V 36~60V 13 Ternary lithium battery (single part 3) System rated voltage 12V formulation (default 3 strings) 24V formula (default 6 strings) 48V formulation (default 12 strings) 3 string defaults Overvoltage (overcharge) / V 10~15V 21~30V 42~60V 13 Overvoltage return / V 10~15V 21~30V 42~60V 12 Increase charging voltage / V 10~15V 21~30V 42~60V 12 Floating payment voltage / V 6~13 12~27V 24~54V 12 Undervoltage /V 6~13 12~27V 24~54V 9 Undervoltage go back voltage /V 6~13 12~27V 24~54V 10 Number of strings 3~4 6~8 14~18 three Lithium iron phosphate (single part 3) System rated voltage 12V method (default three strings) 24V system (default 6 strings) 48V formulation (default 12 strings) 4 string defaults Overvoltage (overcharge) / V 9~12V 18~24V 36~48V 15 Overvoltage return / V 9~12V 18~24V 36~48V 14 Increase charging voltage / V 9~12V 18~24V 36~48V 14 Floating payment voltage / V 9~12V 18~24V 36~48V 13 Undervoltage /V 6~12V 12~24V 24~48V eleven Undervoltage return voltage /V 6~12V 12~24V 24~48V 12 Number of strings 3~4 6~8 14~18 4 Details Images: Note: to understand about more instruction and model, please touch us for FREE fantastically illustrated consumer manual(with varied hybrid contoller product catalogued) Product Application: FAQ 1 desire MARS ENERGY as a carrier of products? (1) Mars Energy is famous brand on the world market in new calories business We have solid R&D technical teams and professional production lines; (2) Mars Energy is a producer specializing in the manufacturing of controller from China It has a complete quality leadership formulation and cost management advantages; (3) Mars Energy is a frontrunner in cross-border e-commerce After many years of operation, Mars Energy has accomplished the mixing of the supply chain ,Cheapest transport charge Fastest to arrive around the globe (4) Mars Energy has established gross sales and after-sales teams in numerous countries, which can present pre-sales steering and after-sales carrier in a local language; (5) Since fitting in 1999, Mars Energy has gained praises from extra and more clients all over the world for its professionalism, responsible perspective and advantageous 2 to attach these three terminals of controller with my wind output wires? (1) To AC wind turbine, anyone of three wires from wind turbine could be linked with any terminal of wind in your controller For they are non-electrode; (2) To DC wind output is 2 wires(Positive Negative) , you can join them with any wind terminals in your controller three many connecting ways person can prefer when utilizing this controller? For the wind charging and Solar charging are independent, so consumer can favor anybody of the ensuing as the connection system : (1) Only join wind turbine generator to fee battery; (2) Only connect solar to price battery; (3) Connect wind turbine and solar to construct a hybrid wind solar power method to fee battery 4 i solely connect wind turbine as generator to payment battery when i am getting my controller? Yes, you would to accomplish that But for the main objective of such controller designs for low strength consumption package charging, such as: road lighting fixtures and tracking and so forth So set up hybrid wind solar method can get better charging warrantly Because maximum of low-power wind turbine is installed in or near to the residential place, wind era efficiency is not high because of the low wind speed and quick working time five to connect my system once I get this controller? We strongly put forward user to put in air change between all DC and AC enter or output Then please switch on the breaker/ air change in this order: (1) First activate the breaker between battery and controller; (2) Second activate the breaker between wind and controller; (3) Third activate the breaker between DC load and controller; (4) Final switch on the breaker between Solar and controller Remark: If you prefer to close down the system, please proceed in the reverse order as above 6 i need to install additional gentle keeping for my power system? Yes, it's best solution to install further gentle conserving 7 the controller to function when the wind speed is simply too fast? (1) For the output voltage or recent from wind generator which beyond the security range, the controller will routinely switch on the brake and gradually slow down Meanwhile, the dump load will start to eat excess current straight (2) But when encountering strong storm weather, such as hurricane, typhoon, it is strongly counseled to place down the wind turbine directly eight to design hybrid wind solar energy formula voltage, 12V, 24V, 48V, which one is best to me? (1) The system voltage is reminiscent of the voltage of the battery pack; (2) Once the battery voltage designed, the input voltage from wind turbine generator and solar modules should be matched per the specs within the parameter table; (3) Therefore, customers can't simply think that more lower voltage design, can get more bigger charging latest but forget about that the immoderate recent has exceeded the operating differ of the controller or battery to break the controller or battery nine designed in MPPT (1) Wind turbine charging followed booster MPPT technology, which makes beneath low wind speed, the Wind turbine&;s electricity can still be used; (2) In the excessive wind velocity or the Wind turbine of strength is beyond the scope of the battery and load absorption, the controller straight released the step-less unloading function,protection formulation of the package 10 the wind generator is attached to the controller, why its running velocity turns into very slow immediately? (1) The battery reaches the floating voltage; (2) The rated output voltage of the wind generator is much larger than the battery, because the velocity of the wind generator is proportional to the output voltage, and the voltage is dragged by means of the battery, so the rate could be very low; eleven wind generator unload load when the controller reveals small current? The controller preserve the all formulation through detecting battery voltage, charging current and temperature and so on When the battery attain floating payment voltage or excessive temperature, the wind generator will unload load, whatever how a lot charging current it's 12 there showing no charging current on LCD screen but the wind is working or the solar is working? Only when the enter voltage of photo voltaic panels or wind generator greater than battery then it will payment the prerequisite is that the battery is correctly related and never entirely charged 13 the LCD would not light up? For the power of controller comes from battery or photo voltaic when its working So please check photo voltaic input or battery as follows (1) The battery didn&;t connect the controller well, please examine the battery and controller connection (2) Battery is damaged, please check and update the battery; (3) In good solar day the solar input is workable or not





Review
0 people rated this product
12V 24V 48V 3000W 5KW Hybrid Wind Solar Charge Controller MPPT Wind Generator Solar System For Lifepo4 Lithium Lead Acid Battery









Free shipping & returns
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection