







Description
This product is usually used for motors with the ensuing voltages: 220V (50Hz, 60Hz) 230V (50Hz, 60Hz) 240V (50Hz, 60Hz) The above 3 voltages are common for this product Single-phase 220V mushy beginning module use range: Petroleum, chemical, fire, construction, metallurgy, building materials, mining, environmental protection and different fields Fans, pumps, belt conveyors, ball mills, automobile washing machines, conveyors and compressors It is an ideal replacement for classic star/delta conversion, auto-coupling buck, magnetic management buck, inverter and other step-down beginning instruments 220V single-phase motor tender start module (motor conversion method) model: SSR-20WA-R1 (1kw) SSR-40WA-R1 (1) SSR-60WA-R1 (2kw) SSR-100WA-R1 (4kw) SSR-150WA-R1 (6kw) SSR-200WA-R1 (8kw) According to the actual working current 5 times: strength ÷ voltage × five in case: Your motor is 8000w strength ÷ 220v voltage × five = (181 should favor 200WA) must choose the parameter closest to that mannequin our gentle start is universal for the motor, regardless of whether or not the motor has a capacitor or not If your motor is working for a long time, the motor above 2000W ought to be equipped with a warmth sink Single phase motor compared to starter module Voltage compatibility: (220V + 0V = single-phase 220V, AC) (230V + 0V = single-phase 230V, AC) (240V + 0V = single-phase 240V, AC) (220V + 220V = two-phase 380V--400V, AC) Frequency: 50Hz, 60Hz Soft start time is adjustable between 0-30 seconds (soft beginning time refers to the complete process 0-220V, 0-380V) Slowly alter the beginning voltage from 0-50? Reaching the rated voltage (220-380V) There are two ways to apply it: 1 After closing the switch, the foremost power can be energized and start delicate beginning 2 Use the swap to control, close the gentle begin to start, open to stop The soft delivery module has 2 programs: 1 has smooth delivery and no delicate give up 2 has smooth start and mushy give up functions (start as many V stops as V stop) note: 1 no longer observe voltage to the swap note: 1 Do not use a multimeter at the load facet to evaluate the standard of the product! 2 Subject to area verify Working environment temperature differ -25°C~60°C





Review
0 people rated this product
220V single-phase motor soft starter module controller2KW4KW6KW8KW motor online soft starting fan pump pressure reducer conveyor













Free shipping & returns
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection