Features:
This product is an upgraded version of the W1308
Added conversion operate in Celsius and Fahrenheit
Fully sealed, water resistant and safer
Application:
Fridge freezer ,display cabinets temperature control, plastic greenhouse, Incubator,Medical equipment, pet house, planting and breeding industry, electrical control cabinet cooling, air flow containers, reptiles insulation, EPS incubator, sauna, PC cases, civil and commercial equipment
Easy and convenient to apply
Specifications:
Temperature control range: -50 ~ a hundred and twenty ° C
Measurement Accuracy: zero ° C
Control accuracy: 0 ° C
Hysteresis accuracy: zero ° C
Refresh rate: zero S
Input Power: AC 110V~220V
Measuring inputs: NTC (10K 0%) Waterproof sensor 0
Output: 1 Channel relay output, ability = 10A
Environmental requirements: -10 ~ 60 ° Humidity 20% -85%
Size: 10*4*2
Work light: Red
Package include:
1 x Temperature Control Switch
------------------------------------------
USER GUIDE
Celsius and Fahrenheit switching
Press and preserve the C/F button for three seconds, the C mode is modified to the F mode, the corresponding indicator gentle is on, after which the C/F button is pressed for three seconds The F mode is changed to the C mode, the corresponding indicator mild is on, and the power off operate is kept
Quick Setup
1 the mode
Press and maintain SET for approximately five seconds to show P0, press SET back to demonstrate the mode
Press +- change mode, H is heating mode, C is cooling mode
2 Set the go back difference:
The hysteresis is also how a lot the fall back after the set temperature stops The default is two
If you should modify, please press and keep SET and let opt for about five seconds to display P0, press +- to switch P1, press ST back to show the difference, press +- to set the adaptation again
3 Set the temperature:
After surroundings the mode and hysteresis, press ENT to substantiate the return At this for time, the display screen exhibits the real-time temperature Press SET screen once and press +- to set the desired temperature
Code desk
P0: operating mode (range: H/C) (default: C)
P1: Hysteresis environment (range: 0) (default: 2)
P2: Setting limit is excessive (range: +120) (default: 120)
P3: Low atmosphere limit (range: -55) (default: -55)
P4: Temperature correction (range: +10~-10) (default: 0)
P5: Delayed delivery (range 0-10 minutes) (default: 0)
P6: High temperature alarm (-55~120) (default: off)
P7: Data lock (on~off) (default: off)
P8: Restore manufacturing facility settings (on~off) (default: off)
In the off state, press and preserve the up and down keys to soon restore the manufacturing facility settings