Descriptions
NEW ARRIVAL GEYA G2R Din Rail 2P 4P ATS Dual Power Automatic Transfer Switch Electrical Selector Switches Uninterrupted Power 25A 40 63A 110V/220V BEST ATS QUALITY IN Buydo---SILVER CONTACT POINT & RED COPPER PARTS & STABLE RELAY CONTROL City Power ⇆ Generator G2R ATS Usage Precautions: 1 220V ATS should not be used with a voltage less than 185V, in any other case the coil may perhaps burn out 2 110V ATS shouldn't be used with a voltage less than 90V, in any other case the coil may burn out 3 The swap cannot be manually switched when in automated mode, otherwise the coil may possibly burn out three 4P ATS make sure right connection of section sequence,otherwise the contacts could burn out General GEYA G2R-63 automated move swap is a PC class infrequent change-over switch, with two-station design (commonly used for A and standby for B), appropriate for AC programs with AC 50-60hz and rated latest 6A-63A The leading operate of the automated transfer swap is when the foremost energy (common strength delivery A) fails, the ATS will mechanically switch to the backup strength (Backup energy supply B) to continue operating (switching velocity <50 milliseconds), which may effectively resolve the worries brought on by power outages When either A and B have electricity, priority is using A Power NOTE: 1 Manual/automatic operation can ensure the opening and shutting performance of electric operation, yet in manual operation , there is not any guarantee due to varied _opening/closing speeds of the operators In handbook operation, there may be probable for immoderate silver alloy loss Therefore, the selector swap must solely be pulled to the guide function in any case energy has been bring to a halt for inspection and maintenance of the operating system and phone information 2, Normally, pull the selector change to the electrical role When manual operation is required, pull the selector change to the guide position After manual operation is complete, pull the selector switch from the manual position to the automatic position The management circuit TSE is straight away energized After the change over is completed, the inner change will injury the coil in the control circuit, and the coil can paintings usually at 85%-110% of the rated working voltage Too low input voltage can cause the coil to overheat and burn out Attention!When handbook operation the mode selection change must be in "manual" role Company Information





Révision
0 people rated this product
GEYA G2R Din Rail 4P ATS Electric Switch Manual Transfer Switch 110V 220V Coil PC Type Switch City Power to Generator 63A


Livraison et retours gratuits
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection