





Descriptions
Multi-channel energy timing sequencer / timing / pulse / random / set off programmable management panel / module PLC 1: Product model: YYD-10 6 sorts of generally used functions, to fulfill more utility requirements; can management as much as 10 solenoid valves, pumps, motors, lights, and so on Freely run; the variety of output teams would be adjusted freely, the maximum output is 10 Output control energy inside 10A 2: Input voltage: voltage DC 7~27V common 3: Output power: can control DC load inside 10A 4: Time range: 0 seconds to 999 minutes, any time adjustable Wiring port description: 1, DC+: enter energy fine 2, DC-: enter power detrimental 3 IN1~6: Signal enter terminal 1~6 (negative trigger) 4, OUT1+~OUT10+: superb terminal; (shared negative) Function list: operate would be arbitrarily set to buy back; any parameter that can be memorized via strength failure (X signifies the number of groups that need to work, can freely replace the variety of groups that deserve to work) P-1X: Give signal 1, output 1~10 approach in collection Give sign 2, output 1~10 way, give up so as Give sign 3, reset P-2X: For signal 1, the output 1~10 channels are sequentially started in series (only one output is working at the similar time), only paintings once in turn; Give the signal again; start back For sign 2, the output 1~10 channels are sequentially started in collection (only one output is working at the similar time), limitless loop Give sign 3, reset P-3X: Give signal 1, output 1~10 channels output for zero moment at regular intervals, only paintings once in turn; give signal again; birth again Give signal 2, output 1~10 way, output 0 second every interval, countless loop Give signal 3, reset P-4X: For the 1st signal 1, the output 1 begins mechanically for a era of time; for the second signal 1, the output 2 starts for a era of time to prevent automatically; Until the last one is done; re-execute the sign again For the first sign 2, the output 1 is started and held; for the second one sign 2, the output 2 is activated; till the last one is started; then the signal is absolutely grew to become off; then the sign is re-executed again Give sign 3, reset P-5X: Give signal 1, each once in a while; routinely beginning 1 channel randomly until strength is bring to a halt Give signal 2, randomly birth 1 way, beginning routinely for a period of time Give signal 3, reset P-6X: Give sign 1, output 1, 2 start, after a era of time, stop routinely Give sign 2, output 3, four start, after a while, stop routinely Give sign 3, output 5, 6 start, after a while, stop mechanically Give signal 4, output 7, eight start, after a era of time, quit routinely Give signal 5, output 9, 10 start, after a era of time, give up robotically Give sign 6, the output 1~10 begins on the similar time, after a period of time, it stops automatically Additional information: 1: For example, set P-16; signify sign 1, output 1~6 channels are sequentially began in sequence; sign 2, output 1~6 channels are sequentially stopped so as 2: The P-1, P-2, and P-3 mode indicators are continually shorted, and the program would be mechanically executed by means of power-on Button environment instructions: Press the 1st K1 Screen display: P -11: K2 and K3 adjustment mode, K4 adjusts the variety of teams that need to work Press the second one K1, the display displays: F001: K2 and K3 alter the time, K4 adjust the decimal point (time unit) Decimal time unit description: XX decimal level in ten, timing range: 0 seconds to ninety nine seconds XXX has no decimal point, timing range: 1 second ~ 999 seconds XXX The decimal point is in one place, the time fluctuate is from 1 minute to 999 mins




Révision
0 people rated this product
Multi-channel power timing sequencer / timing / pulse / random / trigger programmable control panel / module PLC
Livraison et retours gratuits
QWQER Express,
USPS,
DHL
Shopping security
- Safe payment options
- Secure privacy
- Secure logistics
- Purchase protection